![Wacker Neuson DPU 5545He Operator'S Manual Download Page 35](http://html1.mh-extra.com/html/wacker-neuson/dpu-5545he/dpu-5545he_operators-manual_3277957035.webp)
Maintenance
T00997GB.fm
35
5.
Maintenance
5.1
Maintenance schedule
Component
Maintenance work
Maintenance
interval
Drive engine
First oil change and filter.
approx. 8 hours
after initial start-up
Valve clearance
Cold engine: Check valve clearance, and adjust if
necessary.
Inlet valve 0,1 mm - outlet valve 0,2 mm.
Air filter
Check dry type air filter - clean or replace filter
cartridge if necessary (pay attention to the
maintenance indication).
daily
Drive engine
Check oil level, if nec. top up oil.
Centre pole height
setting, transport lock
Regrease.
weekly
V-belt
Check V-belt, if. nec. replace.
monthly
Protective frame
Check attachment screws for tight fit.
Central lifting point
Tow-bar head
Check oil level, top up if necessary.
Drive engine
Oil change, change oil filter.
Keep cooling fins free of dirt, clean dry.
Retighten all accessible screw connections.
every 250 h
Exciter
Oil change.
Battery
Check acid level, if nec. top up with distilled water.
Valve clearance
Cold engine: Check valve clearance, and adjust
if necessary.
Inlet valve 0,1 mm - outlet valve 0,2 mm.
Fuel filter
Change filter.
every 500 h
Summary of Contents for DPU 5545He