SDB-103 Small Diameter Beveler and FF 206 Flange Facer
44
Part No. 16-MAN-01, Rev. 4-1109
E.H. Wachs
Figure 5-29. Remove the rotating head screws using a
3/16” hex wrench.
Installing the Trip Collar
1.
Install the trip collar assembly. The locking screw
must be located close to the air motor housing. Instal-
lation at this position will ensure access to each trip.
Figure 5-30. The trip collar locking screw should be
as close to the air motor housing as possible.
2.
Tighten the trip collar screws.
NOTE
Do not remove
the two screws under the
feed screw.