17
Problems and corrective measures
6
Problems and corrective measures
PROBLEM
REMEDIES
Target device does not receive any or incorrect CAN data
– Check the power supply of the MCG.
Target device does not receive any or incorrect CAN data
–
Check if the CAN cables (CAN High and CAN Low)
are correctly connected to the source CAN bus.
–
Check if the CAN cables (CAN High and CAN Low)
are correctly connected to the target CAN bus.
Target device does not receive any or incorrect CAN data
–
Check the correct termination (terminating resistor) of
the target CAN bus.
Target device does not receive any or incorrect CAN data
–
Check if the MCG version with the correct baud rate
was installed in the vehicle.
Vehicle behaves unusually after installing the MCG
–
Remove the MCG again and contact a workshop.
Vehicle indicates fault messages
–
Remove the MCG again and contact a workshop.