ERC3 Gateway Unit 

First Step Guide   

First Edition 

Thank you for purchasing our product. 
Make sure to read the Safety Guide and detailed Instruction Manual (CD/DVD) included with the product in addition to   
this First Step Guide to ensure correct use. 
This Instruction Manual is original. 
 
 
 
 
 

 Using or copying all or part of this Instruction Manual without permission is prohibited.

 

 The company names, names of products and trademarks of each company shown in the sentences are registered 

trademarks. 

 DeviceNet and CompoNet are a registered mark of ODVA. 

 CC-Link is a registered trademark of Mitsubishi Electric Corporation. 

 PROFIBUS is a registered trademark of PROFIBUS Association. 

 MECHATROLINK is a registered trademark of MECHATROLINK Members Association. 

 EtherCAT® is a registered mark of Beckoff Automation GmbH. 

 EtherNet/IP is a trademark used under the license of ODVA. 

 

Product Check 

This product is comprised of the following parts if it is of standard configuration. 
If you find any fault in the contained model or any missing parts, contact us or our distributor. 
1. Parts 

No. 

Part Name 

Model 

Remarks 

Gateway Unit Main Body 

Refer to “How to read the model plate”, “How to 
read the model No.”

 

 

Accessories

 

2 Power 

Connector 

FMCD1.5/8-ST-3.5 
(Supplier : PHOENIX CONTACT) 

 Emergency Stop 

Recommended cable 
size 
0.5mm

2

 (AWG20) 

 Power Supply 

Recommended cable 
size 
1.25 to 0.5mm

2

 

(AWG16 to 20) 

CC-Link Connector 
(For CC-Link Type) 

MSTB2.5/5-STF-5.08 AU 
(Supplier : PHOENIX CONTACT) 

Terminal Resistance 
(130

Ω

1/2W, 110

Ω

1/2W) 

enclosed one unit each 

DeviceNet Connector 
(For DeviceNet Type) 

SMSTB2.5/5-ST-5.08AU 
(Supplier : PHOENIX CONTACT) 

Prepare a terminal 
resistor separately if this 
controller is to be 
allocated at the terminal. 

Absolute Battery Box (Option)  EGW-ABB (Battery AB-7) 

For Simple Absolute 
Type 

First Step Guide 

 

 

Instruction Manual (DVD) 

 

 

Safety Guide 

 

 

 
2.  Teaching Tool (Please purchase separately) 

A teaching tool such as PC software is necessary when performing the setup for position setting, parameter setting, etc. 
that can only be done on the teaching tool. 
Please prepare either of the following teaching tools. 

No. Part 

Name 

Model 

PC Software 
(Includes RS232C Exchange A Peripheral Communication Cable) 

RCM-101-MW 

PC Software 
(Includes USB Exchange A USB Cable + Peripheral 
Communication Cable) 

RCM-101-USB 

Teaching Pendant (Touch Panel Teaching) 

CON-PTA 

Teaching Pendant (Touch Panel Teaching with deadman switch) 

CON-PDA 

Teaching Pendant   
(Touch Panel Teaching with deadman  TP Adapter (RCB-LB-TG)) 

CON-PGA 

 
3.  Instruction manuals related to this product, which are contained in the instruction manual (DVD). 

No. Name 

Manual 

No. 

ERC3 Gateway Unit Instruction Manual 

ME0302 

ERC3 Actuator with Integrated Controller Instruction Manual 

ME0297 

PC Software 

RCM-101-MW/RCM-101-USB Instruction Manual 

ME0155 

Touch Panel Teaching 

CON-PTA/PDA/PGA Instruction Manual 

ME0295 

 

4.  How to read the model plate 
 
 
 
 
 
 
5.  How to read controller model code 

• 

Gateway unit

 

model 

RCM – EGW – DV 

 
 
 
 
 
 
 

• 

Battery box model 

EGW – ABB – 

 - 

 

 

 
 
 

Basic Specifications

 

List of Specifications 

Number of Controlled Axes 

4 axes MAX. 

Control/Motor Power Supply Voltage 

24V DC 

± 

10% 

Control Power Capacity 

MAX. 1A 

High output setting valid 

(Note 1)

 Rated 

3.5A/MAX. 

4.2A 

Load Current 
(Per axis) 

High output setting invalid 

(Note 1)

Rated 1.2A/MAX. 2.0A 

Capacity of Brake Release Power Source (Per 
axis) 

MAX. 0.15A 

Control Power Capacity for Simple Absolute Unit MAX. 1.4A 

High output setting valid 

(Note 1)

 2.5W 

Heat 
Generation 

High output setting invalid 

(Note 1)

1.9W 

In-Rush Current 

(Note 2)

 MAX. 

60A 

Transient Power Cutoff Durability 

20ms 

Motor Control System 
Applicable Encoder 

Refer to Instruction Manual for the actuator with integrated ERC3 controller 

Cable Length Between Actuator and Gateway MAX. 10m (Use the dedicated cable.) 
Serial Communication Interface 
(SIO Port: Only for teaching) 

RS485 1CH (based on Modbus Protocol) Speed 9.6 to 230.4kbps 

External Interface 

DeviceNet, CC-Link, PROFIBUS-DP, CompoNet, 
MECHATROLINK-I/II, EtherNet/IP, EtherCAT 

Data Setting and Input 

PC Software, Touch Panel Teaching, Gateway Parameter Create Tool 

Data Retention Memory 

Position data and parameters saved in the non-volatile memory of actuator 
via Gateway Unit (There is no limitation in number of writing)

 

Number of Positioning Points 

MAX. 512 points (There is no limit for simple direct and direct indication 
modes) 
(Note)

 

The number of positioning points differs depending on the operation 
pattern select by the parameter setting. 

LED Display 
(Mounted on Front Panel) 

1) Gateway status LEDs 

6 points 

2) Each axis status LEDs 

6 points 

Electromagnetic Brake Compulsory Release 

Can be released with the brake compulsory release switch installed in the 
front panel for each axis 

Protective functions 

Overcurrent Protection 

Protection Function against Electric Shock 

Class I basic insulation 

Insulation Resistance 

500V DC 10M

Ω

 

Cooling Method 

Natural air-cooling 

External Dimensions 

35W × 140H × 105D 

Weight 

Approx. 220g  (DeviceNet Type, CC-Link Type, PROFIBUS Type, 

CompoNet Type, EtherNet/IP Type) 

Approx. 230g  (MECHATROLINK Type) 
Approx. 240g  (EtherCAT Type) 

Ambient Air Temperature 

0 to 40

°

Ambient Humidity 

85%RH or less (non-condensing) 

Ambient Environment 

[Refer to Installation Environment] 

Ambient Storage Temperature 

-20 to 70

°

C  * 0 to 40

°

C for absolute battery 

Ambient storage humidity 

85%RH or less (non-condensing) 

Usable Altitude 

1000m or lower above sea level 

Vibration Durability 

Frequency 10 to 57Hz/ Swing width : 0.075mm 
Frequency 57 to 150Hz/ Acceleration : 9.8m/s

2

 

XYZ Each direction    Sweep time: 10 min.    Number of sweep: 10 times 

Shock Resistance 

150mm/s

2

 11ms Semi-sine wave pulse XYZ Each direction 3 times 

Envi

ro

nm

en

Protection Class 

IP20 

Note 1  Refer to the separate booklet Controller Integrated Actuator for the details of the connected 

actuator (ERC3). 

Note 2  Rush current passes for about 50

μ

s after the power is injected.

<Calculation of 24V DC Power Capacity> 

For the calculation of 24V DC power capacity, figure out the numbers for (1) to (5) below, and then follow 
Step (6). 
(1) Control Power Current Consumption : 1A ·················································································1) 
(2) Current Consumption of Motor Power Supply: 

Sum total of load c (Number of actuator axes equipped with brake × 0.15A) ················2) 

(3) For Simple Absolute Type 

: 0.2A + (0.3A × Number of axes) ····································3) 

(4) Current Consumption at Excitation Phase Detection: 

Add the inrush current for all connected axes············································································4) 

(5) In-Rush Current : 

60A················································································5) 

(6) Selection of Power Supply: 

Usually, the rated current is to be approximately 1.3 times higher than 1) + 2) + 3) above considering 
approximately 30% of margin to the load current. However, considering the current of 4) to 5), even 
though it is a short time, select a power supply with “peak load corresponding” type or that with enough 
capacity. For the current of 4) to 5), it can be avoided from the current consumption occurred at the same 
time by the timing for the emergency stop release (motor power-on) and servo-on being changed. In the 
case that the capacity margin is not sufficient, voltage might be dropped in a moment. In particular, be 
careful of the power unit with the remote sensing function. 

(Note) Make short-circuit on 0V side when separate power sources are used for the control power and 

motor power. 

(Reference)

 

Selection of Power Supply Protection Circuit Breaker 

It is recommended that the power supply protection is conducted on the primary side (AC power side) of 
the 24V DC power supply unit. 
Pay attention to the in-rush current of 24V DC power supply unit and rated cutoff current of the circuit 
breaker. 
•  Rated Breaking Current > Short-circuit Current = Primary Power Supply Capacity/Power Voltage 
•  (Reference) In-rush Current of IAI Power Supply Unit PS241 = 50 to 60A, 3msec 

 

 Specifications of DeviceNet Interface 

Item Specification 

DeviceNet2.0 
Group 2 Dedicated Server 

Communication Protocol 

Network-Powered Insulation Node 

Baud Rate 

Automatically follows the master 

Communication System 

Master-Slave System (Polling) 

Number of Occupied 
Channels 

Refer to “3.4.1 PLC Address Construction by each Operation Mode” in the Instruction Manual for 
ERC3 Gateway Unit. 

Number of Occupied 
Nodes 

1 Node 

Baud Rate 

Max. Network Length

Total Branch Line 

Length 

Max. Branch Line 

Length 

500kbps 100m  39m 
250kbps 250m  78m 

Communication Cable 
Length 

(Note 2)

 

125kbps 500m  156m 

6m 

Communications Cable 

Use the dedicated cable. 

Connector 

(Note 1)

 

MSTBA2.5/5-G-5.08AU (Manufactured by PHOENIX CONTACT or equivalent) 

Consumption Current of 
Communication Power 
Supply 

60mA 

Communication Power 
Supply 

24V DC (Supplied from DeviceNet) 

Note 1  The cable-side connector is a standard accessory. (PHOENIX CONTACT    SMSTB2.5/5-ST-5.08AU) 
Note 2  For T branch communication, refer to the Instruction Manuals for the master unit and programmable controller (PLC) 

to be mounted. 

 

 Specifications of CC-Link Interface 

Item Specification 

Communication Protocol  CC-Link ver1.1 or ver2 
Station Type 

Remote Device Station (MAX. four stations occupied) 

Baud Rate 

10M/5M/2.5M/625k/156kbps 

Communication System 

Broadcast Polling System 

Number of Connectable 
Stations 

Refer to “3.4.1 PLC Address Construction by each Operation Mode” in the Instruction Manual for 
ERC3 Gateway Unit. 

Baud Rate (bps) 

10M 

5M 

2.5M 

625k 

156k 

Communication Cable 
Length 

(Note 2)

 

Total Cable Length (m) 

100 

160 

400 

900 

1200 

Communications Cable 

Use the dedicated cable. 

Connector 

(Note 1)

 

MSTB2.5/5-GF-5.08 AU (Manufactured by PHOENIX CONTACT or equivalent) 

Note 1  The cable-side connector is a standard accessory. (PHOENIX CONTACT    MSTB2.5/5-STF-5.08 AU) 
Note 2  For T branch communication, refer to the Instruction Manuals for the master unit and programmable PLC to be 

mounted. 

 

 Specifications of PROFIBUS-DP Interface 

Item Specification 

Communication Protocol  PROFIBUS-DP 
Baud Rate 

Automatically follows the master 

Communication System 

Hybrid System (Master-Slave System or Token Passing System) 

Number of Occupied 
Stations 

Refer to “3.4.1 PLC Address Construction by each Operation Mode” in the Instruction Manual for 
ERC3 Gateway Unit. 

MAX. Total Network 

Baud Rate 

Cable Type 

100m 12,000/6,000/3,000kbps 
200m 1,500kbps 
400m 500kbps 
1000m 187.5kbps 

Communication Cable 
Length 

(Note 2)

 

1200m 9.6/19.2/93.75kbps 

Type A Cable 

Communications Cable 

STP cable AWG18 

Connector 

(Note 1)

 

9-pin female D-sub Connector 

Transmission Path Format  Bus/Tree/Star 

Note 1  Please prepare a 9-pin male D-sub connector for the cable-end connector. 
Note 2  For T branch communication, refer to the Instruction Manuals for the master unit and programmable PLC to be 

mounted. 

 

<Series> 

 

<Type> 

EGW  : Drive cutoff relay mounted 
EGWG  : Drive cutoff relay not mounted 

 

<Type of Connected Field Network> 

DV : DeviceNet Type 
CC : CC-Link Type 
PR : PROFIBUS-DP Type 
CN : CompoNet Type 
ML : MECHATROLINK Type 
EP : EtherNet/IP Type 
EC : EtherCAT Type 

Model 
Serial number 

Warning :  Operation of this equipment requires detailed installation and operation instructions which are 

provided on the CD/DVD Manual included in the box this device was packaged in. It should be 

retained with this device at all times. 

 

A hardcopy of the Manual can be requested by contacting your nearest IAI Sales Office listed at   

the back cover of the Instruction Manual or on the First Step Guide. 

<Second Unit Gateway Unit > 

  Number of Connected Axes for Simple Absolute Type

 

<First Unit Gateway Unit > 

  Number of Connected Axes for Simple Absolute Type

 