background image

 

6

 - 

GAS CONNECTION 

All  gas  supply  connections  and  any  pipe  joint  compound  must  be  resistant  to 

the action of propane gases. 

Purge  the  supply  line  to  cle an  out  any  dust,  dirt,  or  any  foreign  matter  before  connecting 
the line to the unit. 

Codes  require  that  a  gas  shut -off  valve  be  installed  in  the  gas  line  ahead  of  the 
charbroiler.  The gas supply line must be at least the equivalent of ¾” iron pipe.      

A  pressure  regulator  is  supplied  and  must  be  installed  outside  of  the  broiler  when  making 
the  gas  supply  connection.    Standard  orifices  are  set  for  4"WC  (W ater  Column)  for 
Natural  Gas 

—  10"WC  (Water  Column)  for  Propane.    Use  the 

1

/

8

”  pipe  tap  on  the  burner 

manifold  for  checking  pressure.    Make  sure  the  gas  piping  is  clean  and  free  of 
obstructions, dirt, and piping compound.  

An  adequate  gas  supply  is  necessary.    Undersized  or  low  pressure  lines  will  restrict  the 
volume  of  gas  required  for  satisfactory  performa nce.    A  minimum  supply  pressure  of  7" 
W.C.  for  natural  gas  and  11"  W .C.  for  propane  gas  is  recommended.    W ith  all  units 
operating  simultaneously,  the  manifold  pressure  on  all  units  should  not  show  any 
appreciable drop.   

When  testing  the  gas  supply  piping  system,  if  test  pressures  exceed  ½  psig  (3.45  kPa), 
the  charbroiler  and  its  individual  shutoff  valve  must  be  disconnected  from  the  gas  supply 
piping  system.    W hen  test  pressures  are  ½  psig  (3.45  kPa)  or  less,  the  charbroiler  must 
be  isolated  from  the  gas  supply  piping  system  by  closing  its  individual  manual  shut -off 
valve during any pressure testing of the system.  

 

Prior  to  lighting,  check  all  joints  in  the  gas  supply  line  for  leaks.  

Use soap and water solution.  Do not use an open flame.  

 

GAS PRESSURE REGULATOR INSTALLATION 

This  charbroiler  is  supplied  with  a  convertible  gas  pressure  regulator  preset   at 

4”  Water 

Column  (W .C.)  for  natural  gas.  No  further  adjustment  should  be  required.   Install  the 
regulator  as  close  to  the  charbroiler  on  the  gas  supply  line  as  possible.  Make  sure  that 
the  arrow  on  the  underside  of  the  regulator  is  oriented  in  the  direction  of  gas  flow  to  the 
charbroiler  (Fig.  2)  and  the  regulator  is  positioned  with  the  vent  plug  and  conversion  plug 
cover upright (Fig. 3).

 

 

Fig. 2 

 

Fig. 3 

Summary of Contents for Wolf VCRB25

Page 1: ...UTURE USE FORM F 38307 9 15 INSTALLATION OPERATION MANUAL FOR MEDIUM DUTY GAS CHARBROILERS VCRB47 MODELS VCRB25 VCRB36 VCRB47 WCRB25 WCRB36 WCRB47 For additional information on Vulcan or to locate an...

Page 2: ...IMPORTANT IN THE EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER...

Page 3: ...This charbroiler was inspected before leaving the factory The carrier assumes full responsibility for the safe delivery upon acceptance of the shipment Check for possible shipping damage immediately...

Page 4: ...ns of ANSI Z223 1 NFPA 54 latest edition and NFPA 96 latest edition in the United States of America or CAN CSA 149 1 latest edition and CAN CSA149 2 latest edition in Canada and approved by the author...

Page 5: ...LEVELING It is important that the charbroiler is level front to back and left to right Areas of uneven heat distribution will occur on an unleveled unit The charbroiler is equipped with adjustable leg...

Page 6: ...r propane gas is recommended With all units operating simultaneously the manifold pressure on all units should not show any appreciable drop When testing the gas supply piping system if test pressures...

Page 7: ...ting check all joints in the gas supply line for leaks Use soap and water solution Do not use an open flame CASTER EQUIPPED CHARBROILERS Charbroilers mounted on stands with casters must use a flexible...

Page 8: ...provide a slight yellow tip on the flame Air shutters on the main burners must be individually adjusted to provide a blue flame All traces of yellow should be adjusted out of the burner flame The char...

Page 9: ...n gas shut off valve OFF Make sure all individual burner valves are off before relighting PREHEATING THE CHARBROILER Allow the charbroiler to preheat for 30 minutes Rub grates with cooking oil before...

Page 10: ...off or clean debris from unit This will cause a buildup of heat that can potentially damage and warp components of the charbroiler MAINTENANCE The charbroiler and its parts are hot Use care when oper...

Page 11: ...adjusted B Appliance is not level side to side C Improperly adjusted burner Uneven heat front to back A Appliance is not level front to back B Faulty ventilation C Improperly adjusted burner Pilot ou...

Page 12: ...12 NOTES...

Page 13: ...12 REMARQUES...

Page 14: ...avant vers l arri re A L appareil n est pas au niveau de l avant vers l arri re B La ventilation est d fectueuse C Le br leur est mal r gl Panne de la veilleuse d allumage A La veilleuse d allumage e...

Page 15: ...d bris de l l ment Cela provoquera une augmentation de la chaleur qui peut potentiellement endommager ou d former les composants du gril ENTRETIEN Le gril et ses pi ces sont chauds Faites attention l...

Page 16: ...SES Pour fermer compl tement Fermez le robinet d arr t principal du gaz Assurez vous que toutes les soupapes individuelles des br leurs sont ferm es avant de rallumer PR CHAUFFAGE DU GRIL Pr chauffez...

Page 17: ...Les obturateurs d air des principaux br leurs doivent tre r gl s individuellement afin d offrir une flamme bleue Toutes les traces de jaune devraient tre limin es d e la flamme des br leurs Le gril e...

Page 18: ...nt l allumage v rifiez tous les joints dans la conduite d alimentation en gaz pour les fuites Uti lisez une solution d eau et savon Ne pas utiliser une flamme nue GRILS MUNIS DE ROULETTES Les grils su...

Page 19: ...el et de 28 cm CE pour le gaz propane Avec tous les l ments fonctionnant en m me temps la pression d admission sur tous les l ments ne devrait pas d montrer une baisse notable Lorsque vous valuez la t...

Page 20: ...que le gril soit mis niveau de l avant vers l arri re et de la gauche vers la droite Il se produira des zones o la distribution de la chaleur sera in gale dans un appareil qui n est pas mis niveau Le...

Page 21: ...applicables des normes ANSI Z223 1 NFPA N 54 et NFPA N 96 ditions les plus r centes aux tats Unis d Am rique ou les normes CAN CSA 149 1 et CAN CSA149 2 ditions les plus r centes au Canada le tout suj...

Page 22: ...LATION D BALLAGE Ce gril a t inspect avant de quitter l usine En acceptant sa livraison le transporteur prend l enti re responsabilit de le livrer en toute s curit Imm diatement apr s la livraison v r...

Page 23: ...ECT E FERMEZ LES UNIT S DU ROBINET D ARR T PRINCIPAL ET CONTACTEZ VOTRE COMPAGNIE DE GAZ OU VOTRE FOURNISSEUR DE GAZ LOCAL AFIN D OBTENIR DU SERVICE POUR VOTRE S CURIT NE PAS ENTREPOSER OU UTILISER DE...

Page 24: ...00 North Point Blvd Baltimore MD 21222 GARDER CE MANUAL POUR UNE UTILISATION FUTURE FORMULAIRE F 38307 9 15 MANUEL D INSTALLATION ET D EMPLOI POUR GRILS AU GAZ FONCTION MOYENNE VCRB47 MODELS VCRB25 VC...

Reviews: