Vulcan-Hart Wolf VCRB25 Installation & Operation Manual Download Page 22

 

3

 - 

IN

ST

AL

LA

TIO

N, 

EM

PL

OI 

ET

 E

NT

RE

TIE

N D

ES

 

GR

IL

S A

U G

AZ

 À

 F

ON

CT

IO

N M

OY

EN

NE

 

 

RA

 

Le

gr

ils

 a

ga

de

 c

om

pto

ir

 s

on

co

us

 à

 d

es

 f

in

co

mm

er

cia

le

se

ule

me

nt 

et 

off

re

nt 

un

ch

ale

ur

 a

ga

ra

pid

e, 

eff

ic

ac

e. 

 C

ha

qu

br

ûle

ur

 e

st 

co

ntr

ôlé

 p

ar

 u

ne

 s

ou

pa

pe

 à

 g

az

 r

ég

la

ble

Le

ra

dia

nts

 

mo

ulé

so

nt 

sit

dir

ec

te

me

nt 

so

us

 

ch

aq

ue

 

br

ûle

ur

 

afi

de

 

ma

in

te

nir

 

un

te

mp

éra

tu

re

 u

nif

orm

e. 

Le

ra

dia

nts

 s

’e

nlè

ve

nt 

fa

cil

em

en

po

ur 

le

 n

ett

oy

ag

lo

rs

qu

’il

so

nt 

re

fr

oid

is

 

Le

gr

ill

es

 s

up

ér

ie

ur

es

 e

fo

nte

 r

és

is

ta

nte

 s

on

ve

rs

ib

le

po

ur

 p

er

me

ttr

à 

la

 s

ur

fa

ce

 d

la

 

gr

ill

de

 c

uis

so

d'ê

tr

mis

à 

pla

ou

 i

nc

lin

ée

 e

to

ta

lit

é 

ou

 e

pa

rti

e. 

 L

es

 r

ain

ur

es

mo

ulé

es

 

da

ns

 

le

gr

ill

es

 

su

rie

ur

es

pe

rm

ett

en

l'é

co

ule

me

nt 

du

 

gr

as

 

et 

du

is

en

l'é

va

se

me

nt 

lo

rs

qu

'e

lle

so

nt 

in

cli

es

 

ve

rs

 

l'a

va

nt.

 

 

 

Un

 

tir

oir

 

à 

gr

ais

se

 

es

fo

ur

ni 

afi

de

 

re

cu

eil

lir

 

l’é

co

ule

me

nt 

du

 g

ra

s; 

il 

s’o

uv

re

 p

ar 

le

 d

ev

an

t p

ou

r v

éri

fie

r o

u v

id

er.

 

 

 

Mod

èle

 

Nombre de

 brû

leu

rs

 

Déb

it 

calor

ifi

que BT

U/h 

 

VC

RB

25 /

 W

CR

B25

 

58 00

VC

RB

36 /

 W

CR

B36

 

87 00

VC

RB

47 /

 W

CR

B47

 

116 000

 

 

IN

ST

AL

LA

TIO

 

 

BA

LL

AG

 

Ce

 g

ril

 

été

 in

sp

ec

 a

va

nt 

de

 q

uit

te

l’u

sin

e. 

En

 a

cc

ep

ta

nt 

sa

 li

vra

is

on

le

 tr

an

sp

ort

eu

pre

nd

  

l’e

nti

ère

 r

es

po

ns

ab

ili

 d

le

 li

vre

en

 t

ou

te

 s

éc

uri

Im

dia

te

me

nt 

ap

la

 li

vra

is

on

rif

ie

s’i

l a

 e

ffe

cti

ve

me

nt 

su

bi 

de

s d

om

ma

ge

s p

en

da

nt 

le

 tr

an

sp

ort

 

S’il

 s

’a

re

 q

ue

 le

 g

ril

 a

 é

 e

nd

om

ma

, v

eu

ill

ez

 s

uiv

re

 le

s p

ro

du

re

s s

uiv

an

te

s :

 

 

1. 

Le

 tr

an

sp

or

te

ur

 d

oit

 ê

tr

e a

ve

rti

 d

an

s l

es

 5

 jo

ur

s o

uv

ra

ble

s s

uiv

an

t l

a r

éc

ep

tio

n.

 

2. 

Le

s g

en

s d

u t

er

min

us

 lo

ca

l d

u t

ra

ns

po

rte

ur

 d

oiv

en

t ê

tr

e a

vis

és

 im

dia

te

me

nt 

lo

rs

 d

la 

   

  

co

uv

ert

e d

es

 d

om

ma

ge

s (

in

diq

ue

z l

’h

eu

re

, l

a d

ate

 e

t à

 q

ui 

vo

us

 a

ve

z p

arl

é) 

et 

as

su

re

z l

   

  s

uiv

i e

n c

on

fir

ma

nt 

le

s f

ait

s p

ar

 é

cr

it 

ou

 p

ar

 c

om

mu

nic

ati

on

 é

le

ctr

on

iq

ue

3. 

Po

ur 

fin

s d

’in

sp

ec

tio

n, 

to

ut 

le

 m

até

rie

l d

’e

mb

all

ag

e o

rig

in

al 

do

it 

êtr

e c

on

se

rv

é. 

4. 

Le

 g

ril

 n

e d

oit

 p

as

 a

vo

ir

 é

 d

ép

la

, i

ns

ta

llé

 o

u m

od

ifi

é.

 

5. 

Av

is

ez

 le

 S

er

vic

e à

 la

 c

lie

ntè

le

 d

e V

ulc

an

 im

dia

te

me

nt 

en

 fa

is

an

t l

e (

80

0)

 8

14

-2

02

8. 

 

ba

lle

z s

oig

ne

us

em

en

t v

otr

e g

ril

 e

t a

ss

ur

ez

-

vo

us

 q

u’a

uc

un

e p

ce

 n

’a

 é

 je

e a

ve

l’e

mb

all

ag

e. 

Un

 ré

gu

la

te

ur 

de

 p

re

ss

io

n c

on

çu

 p

ou

r f

on

cti

on

ne

r a

ve

c l

e b

le

ur 

a é

 

fo

ur

ni 

et 

do

it 

êtr

e i

ns

ta

llé

 a

va

nt 

qu

e l

e g

ril

  s

oit

 m

is

 e

n s

er

vic

e (

Co

ns

ult

ez

 IN

TA

LL

AT

IO

DU

 R

ÉG

UL

AT

EU

R D

E P

RE

SS

IO

N D

U G

AZ

 d

an

s c

e m

an

ue

l).

 

Summary of Contents for Wolf VCRB25

Page 1: ...UTURE USE FORM F 38307 9 15 INSTALLATION OPERATION MANUAL FOR MEDIUM DUTY GAS CHARBROILERS VCRB47 MODELS VCRB25 VCRB36 VCRB47 WCRB25 WCRB36 WCRB47 For additional information on Vulcan or to locate an...

Page 2: ...IMPORTANT IN THE EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER...

Page 3: ...This charbroiler was inspected before leaving the factory The carrier assumes full responsibility for the safe delivery upon acceptance of the shipment Check for possible shipping damage immediately...

Page 4: ...ns of ANSI Z223 1 NFPA 54 latest edition and NFPA 96 latest edition in the United States of America or CAN CSA 149 1 latest edition and CAN CSA149 2 latest edition in Canada and approved by the author...

Page 5: ...LEVELING It is important that the charbroiler is level front to back and left to right Areas of uneven heat distribution will occur on an unleveled unit The charbroiler is equipped with adjustable leg...

Page 6: ...r propane gas is recommended With all units operating simultaneously the manifold pressure on all units should not show any appreciable drop When testing the gas supply piping system if test pressures...

Page 7: ...ting check all joints in the gas supply line for leaks Use soap and water solution Do not use an open flame CASTER EQUIPPED CHARBROILERS Charbroilers mounted on stands with casters must use a flexible...

Page 8: ...provide a slight yellow tip on the flame Air shutters on the main burners must be individually adjusted to provide a blue flame All traces of yellow should be adjusted out of the burner flame The char...

Page 9: ...n gas shut off valve OFF Make sure all individual burner valves are off before relighting PREHEATING THE CHARBROILER Allow the charbroiler to preheat for 30 minutes Rub grates with cooking oil before...

Page 10: ...off or clean debris from unit This will cause a buildup of heat that can potentially damage and warp components of the charbroiler MAINTENANCE The charbroiler and its parts are hot Use care when oper...

Page 11: ...adjusted B Appliance is not level side to side C Improperly adjusted burner Uneven heat front to back A Appliance is not level front to back B Faulty ventilation C Improperly adjusted burner Pilot ou...

Page 12: ...12 NOTES...

Page 13: ...12 REMARQUES...

Page 14: ...avant vers l arri re A L appareil n est pas au niveau de l avant vers l arri re B La ventilation est d fectueuse C Le br leur est mal r gl Panne de la veilleuse d allumage A La veilleuse d allumage e...

Page 15: ...d bris de l l ment Cela provoquera une augmentation de la chaleur qui peut potentiellement endommager ou d former les composants du gril ENTRETIEN Le gril et ses pi ces sont chauds Faites attention l...

Page 16: ...SES Pour fermer compl tement Fermez le robinet d arr t principal du gaz Assurez vous que toutes les soupapes individuelles des br leurs sont ferm es avant de rallumer PR CHAUFFAGE DU GRIL Pr chauffez...

Page 17: ...Les obturateurs d air des principaux br leurs doivent tre r gl s individuellement afin d offrir une flamme bleue Toutes les traces de jaune devraient tre limin es d e la flamme des br leurs Le gril e...

Page 18: ...nt l allumage v rifiez tous les joints dans la conduite d alimentation en gaz pour les fuites Uti lisez une solution d eau et savon Ne pas utiliser une flamme nue GRILS MUNIS DE ROULETTES Les grils su...

Page 19: ...el et de 28 cm CE pour le gaz propane Avec tous les l ments fonctionnant en m me temps la pression d admission sur tous les l ments ne devrait pas d montrer une baisse notable Lorsque vous valuez la t...

Page 20: ...que le gril soit mis niveau de l avant vers l arri re et de la gauche vers la droite Il se produira des zones o la distribution de la chaleur sera in gale dans un appareil qui n est pas mis niveau Le...

Page 21: ...applicables des normes ANSI Z223 1 NFPA N 54 et NFPA N 96 ditions les plus r centes aux tats Unis d Am rique ou les normes CAN CSA 149 1 et CAN CSA149 2 ditions les plus r centes au Canada le tout suj...

Page 22: ...LATION D BALLAGE Ce gril a t inspect avant de quitter l usine En acceptant sa livraison le transporteur prend l enti re responsabilit de le livrer en toute s curit Imm diatement apr s la livraison v r...

Page 23: ...ECT E FERMEZ LES UNIT S DU ROBINET D ARR T PRINCIPAL ET CONTACTEZ VOTRE COMPAGNIE DE GAZ OU VOTRE FOURNISSEUR DE GAZ LOCAL AFIN D OBTENIR DU SERVICE POUR VOTRE S CURIT NE PAS ENTREPOSER OU UTILISER DE...

Page 24: ...00 North Point Blvd Baltimore MD 21222 GARDER CE MANUAL POUR UNE UTILISATION FUTURE FORMULAIRE F 38307 9 15 MANUEL D INSTALLATION ET D EMPLOI POUR GRILS AU GAZ FONCTION MOYENNE VCRB47 MODELS VCRB25 VC...

Reviews: