CAUTIONS (Continued)
CLEARANCES:
FROM THE TERMINATION OF THE
APPLIANCE FLUE VENT TO THE FILTERS OF THE
HOOD VENTING SYSTEM, AN 18 INCH MINIMUM
CLEARANCE MUST BE MAINTAINED.
REFERENCE: ANSI/NFPA 96-1984 4-1.2.2.2. OF THE
NATIONAL FIRE PROTECTION ASSOCIATION, INC.,
BATTERYMARCH PARK, QUINCY, MA 02269. AND
NATIONAL BUILDING CODE 1976 SEC. 1015.7b (2)
OF THE AMERICAN INSURANCE ASSOCIATION
ENGINEERING AND SAFETY SERVICE, 85 JOHN
STREET, NEW YORK, N.Y. 10038.
LOADING:
BEFORE LOADING THE OVEN SET THE
LOAD CONTROL DIAL TO THE PROPER SETTING
FOR THE PRODUCT AND THE COOKING LOAD
(SEE SEPARATE
COOKING CHART
).
OPENING OVEN DOORS:
BEFORE OPENING THE
OVEN DOORS, PUSH THE AUXILIARY FAN SWITCH
TO THE "OFF" POSITION.
OPENING OVEN DOORS WILL AUTOMATICALLY
CUT "OFF" THE FAN AND THE HEATING
ELEMENTS, BUT IF THE FAN SWITCH IS NOT
PUSHED TO THE "OFF" POSITION, HOT AIR
GATHERED WITHIN THE OVEN CAVITY MAY BE
PUSHED OUT WHEN THE DOORS ARE OPENED.
CAUTION: DO NOT
STAND DIRECTLY IN
FRONT OF THE OVEN WHILE
OPENING DOORS
WHEN OPENING THE DOORS, THE OPERATOR
SHOULD PULL DOOR HANDLES OPEN WHILE
SIMULTANEOUSLY STEPPING BACK AWAY FROM
THE FRONT OF THE UNIT.
LOAD THE OVEN AS QUICKLY AS POSSIBLE TO
CONSERVE HEAT. CENTER PANS ON THE RACKS.
HI LIMIT:
IS A PROTECTIVE DEVICE WHICH
SENSES THE TEMPERATURE OF THE UNIT TO
PREVENT APPLIANCE OVERHEATING.
THE HI LIMIT OPERATES INDEPENDENTLY AND
WILL AUTOMATICALLY CAUSE UNIT SHUTDOWN
SHOULD THE PRIMARY CONTROL FAIL.
IF THIS SITUATION OCCURS,
DO NOT
ATTEMPT
TO BYPASS THE HI LIMIT. SHUT UNIT DOWN AND
CONTACT A SERVICE AGENCY.
4