7
3. 31-Band Graphic Equalizer Menu (GEQ_)
Graphic EQ parameters can be set by pressing the
Cursor
push-button to advance from
GEQ#
to
Level
. (Use
the
Cursor
push-button to go backward from to
Level
to
GEQ#
). Use the Data wheel to change the parameter’s
settings.
GEQ#
– Selects one of the 31 available Equalizers bands. The frequency for each band is displayed
LEVEL
– Graphic EQ level gain. The EQ level can be set from -30.00dB to +15.00dB in 0.25dB steps.
4. XOver Menu
Crossover parameters can be set by pressing the
Cursor
push-button to advance from
TYPL
to
FRQL
,
SLPL
,
TYPH
,
FRQH
and finally to SLPH. (Use the
Cursor
push-button to go backward from
SLPH
to
FRQH
,
TYPH
,
SLPL
,
FRQL
, then to
TYPL
). Use the Data wheel to change the parameter’s settings.
TYPL
– Choose between Butterworth, Linkwitz-Riley or Bessel crossover Filter Types for the low
frequency crossover point (high pass).
FRQL
– Filter cut-off Frequency of low frequency crossover point (high pass). Ranges from 20 to 20,000Hz
in either 1 Hz steps or 1/36 octave steps. The frequency steps can be selected in the System Menu.
GEQ#:1 f=20
I1:______ GEQ1
LEVEL:0.00dB
I1:______ GEQ1
TYPL:Off
I1:______ XOver
TYPL:Link-Riley
I1:______ XOver
TYPL:Butterworth
I1:______ XOver
TYPL:Bessel
I1:______ XOver
FRQL:1000Hz
I1:______ XOver
Cursor
Cursor
Menu
Menu
Data