Description and use
The appliance you have purchased is an in-line extractor fan designed for direct extraction (outside or into short ducts),
compatible with wall / panel, false wall, ceiling and false ceiling installation. The appliance is protected against jets of
water (IP45 protection rating), so it is suitable for rooms with a high degree of humidity. All the models are equipped with
a motor with ball bearings. The range consists of 10 models, of standard diameter equal to 100 and 120 mm, with
different technical data, consumptions and items supplied: (see "Installation" and "Use" for a more detailed description
of the various functions:
ME 100/4” LL and 120/5” LL
: basic, two-speed versions;
ME 100/4” LL TP and 120/5” LL TP
: versions with advanced timer. the appliance is equipped with a PCB that permits
time-lagged switching on and/or off at the Vmin or Vmax speed. The length of the time-lagging for switching on and off,
as well as the operating speed, can be set during installation. In addition, the appliance can run automatic switch-on
cycles.
ME 100/4” LL TP HCS and 120/5” LL TP HCS
: version with advanced timer and humidity sensor: the appliance is
equipped with a PCB including a humidity sensor that can automatically activate the system when the ambient relative
humidity values exceed a threshold the installer can set on four values:
60%RH, 70%RH, 80%RH, 90%RH (70%RH is the factory default value);
the PCB moreover permits time-lagged switching on and/or off at the Vmin or Vmax speed.
ME 100/4” LL T PIR and 120/5” LL T PIR
: version with simplified timer at a speed of Vmin or Vmax and PIR presence
sensor: the appliance is equipped with a PCB including a PIR sensor that can automatically activate the system when it
detects a presence; the PCB also permits time-lagged switching off. The length of the switch-off delay, as well as the only
operating speed, Vmin or Vmax, can be set during installation.
ME 100/4” LL T and 120/5” LL T
: version with simplified timer at one speed: the appliance is equipped with a PCB that
permits time-lagged switching off. The length of the switch-off delay, as well as the only operating speed, Vmin or Vmax,
can be set during installation.
These appliances are designed for use in residential and commercial
properties.
ENGLISH
Summary of Contents for ME 100/4" LL
Page 4: ...4 Vortice ZH 66 67 68 68 68 69 71 71 72 82 73 74 77 77 77 79 81 81 82...
Page 67: ...67 Vortice a b 8 Vortice Vortice Vortice a b c 400mm 50 122 HCS PIR A 1 3mm III...
Page 72: ...72 WEEE 2012 19 EC...
Page 74: ...74 vortice 0...
Page 75: ...75 10 2 0 Vortice e Vortic Vortice Vortice 400 50 122 T HCS PIR 1...
Page 76: ...76 3 M 220 240 230...
Page 83: ...83 7 7 8 8 9 9 9 10 9 10 a 10 a...
Page 85: ...85 16 16 16 A B ON OFF 1 2 3 4 5 6 16 16 17 19 1 1 2 2 18 1 1 2 2 OFF 120 ON 100 ON OFF...
Page 89: ...89...