Series M22/M23/M24 Instruction Manual
Chapter 3 Operation
M-000-00010
3-9
Alarms Menu
Password
ENTER
Use
keys to access menus
Alarms
Menu
Relay Alarm 1
More >
ENTER
Run Mode
Relay Alarm 2
More >
Relay Alarm 3
More >
Alarm LOG
xx Files (ENTER)
Clear Alarm LOG?
YES or NO
<Measure> units
xxxx
xxxx
xxxx
Alarm File
Time
Date
(Press EXIT to return
to Alarm LOG)
* see below
Physical Layer does not exist on Two Wire
Mass - Accessible via HART
<Measure>
None
Mass
Volume
Temp 1,2
Press
Density
** Energy
<Measure>
None
Mass
Volume
Temp 1,2
Press
Density
** Energy
<Measure>
None
Mass
Volume
Temp 1,2
Press
Density
** Energy
<Mode>
None
HIGH Alarm (>)
LOW Alarm (<)
<Mode>
None
HIGH Alarm (>)
LOW Alarm (<)
<Mode>
None
HIGH Alarm (>)
LOW Alarm (<)
<Measure> units
<Measure> units
*
**
Energy EMS Meters Only
Example for Setting an Alarm
The following shows how to set Relay Alarm 1 to activate if the mass flow rate is greater than 100 lb/hr. You can
check the alarm configuration in the Run Mode by pressing the
keys until Alarm [1] appears. The lower line
displays the mass flow rate at which the alarm activates. Note: all outputs are disabled while using the Setup Menus.
First, set the desired units of measurement:
1.
Use
keys to move to the Units Menu (see to page 3-12).
2.
Press
key until Mass Flow Unit appears. Press
ENTER
.
3.
Press
key until lb appears in the numerator. Press
key to move the underline cursor to the
denominator. Press the
key until hr appears in the denominator. Press
ENTER
to select.
4.
Press
key until Units Menu appears.
Second, set the alarm:
1.
Use
keys to move to the Alarms Menu.
2.
Press the
key until Relay Alarm 1 appears.
3.
Press
key to access Measure selections. Press
ENTER
and use the
key to select Mass. Press
ENTER
.
4.
Press
key to select the alarm Mode. Press
ENTER
and use
key to select HIGH Alarm. Press
ENTER
.
5.
Press
key to select the value that must be exceeded before the alarm activates. Press
ENTER
and use
keys to set 100 or 100.0. Press
ENTER
.
6.
Press the
EXIT
key to save your changes. (Alarm changes are always permanently saved.)
(Up to three relay alarm outputs are available depending on meter configuration.)
Summary of Contents for Pro-T
Page 10: ...Table of Contents Series M22 M23 M24 Instruction Manual 0 10 M 000 00010...
Page 20: ...Chapter 1 Introduction Series M22 M23 M24 Instruction Manual 1 10 M 000 00010...
Page 60: ...Chapter 2 Installation Series M22 M23 M24 Instruction Manual 2 40 M 000 00010...
Page 126: ...Chapter 5 Troubleshooting Repair Series M22 M23 M24 Instruction Manual 5 16 M 000 00010...
Page 140: ...Appendix B Approvals Series M22 M23 M24 Instruction Manual B 4 M 000 00010...
Page 150: ...Appendix D Glossary Series M22 M23 M24 Instruction Manual D 4 M 000 00010...