![VorTek Pro-T Instruction Manual Download Page 43](http://html1.mh-extra.com/html/vortek/pro-t/pro-t_instruction-manual_1050443043.webp)
Series M22/M23/M24 Instruction Manual
Chapter 2 Installation
M-000-00010
2-23
Pulse Output Connections
The pulse output is used for a remote counter. When the preset volume or
mass (defined in the totalizer settings, see page 3-10) has passed the me-
ter, the output provides a 50 millisecond square pulse.
The pulse output requires a separate 5 to 36 VDC power supply. The
pulse output optical relay is a normally-open single-pole relay. The relay
can conduct a current up to 40 mA. It is isolated from the meter electron-
ics and power supply.
Figure 2-17. Isolated Pulse Output Using External Power Supply
Figure 2-18. Non-Isolated Pulse Output Using External Power Supply
Summary of Contents for Pro-T