Appendix A Specifications
Series M22/M23/M24 Instruction Manual
A-4
M-000-00010
M23 Pressure Ratings
Probe Seal
Process
Connection
Material
Rating
Ordering
Code
Compression
Fitting
2-inch MNPT
316L SS
ANSI 600 lb
CNPT
2-inch 150 lb flange,
DN50 PN16
316L SS
ANSI 150
lb, PN16
C150,
C16
2-inch 300 lb flange,
DN50 PN40
316L SS
ANSI 300
lb, PN40
C300,
C40
2-inch 600 lb flange,
DN50 PN63
316L SS
ANSI 600
lb, PN63
C600,
C64
Packing Gland
2-inch MNPT
316L SS
50 psig
PNPT
2-inch 150 lb flange,
DN50 PN16
316L SS
50 psig
P150,
P16
2-inch 300 lb flange,
DN50 PN40
316L SS
50 psig
P300,
P40
Packing Gland with
Removable Retractor
2-inch MNPT
316L SS
ANSI 300 lb
PM, RR
2-inch 150 lb flange,
DN50, PN16
316L SS
ANSI 150 lb
P150,
P16,RR
2-inch 300 lb flange
316L SS
ANSI 300 lb
P300,
P40, RR
Packing Gland with
Permanent Retractor
2-inch MNPT
316L SS
ANSI 600 lb
PNPTR
2-inch 150 lb flange,
DN50 PN16
316L SS
ANSI 150 lb
P150R,
P16R
2-inch 300 lb flange,
DN50, PN40
316L SS
ANSI 300 lb
P300R,
P40R
2-inch 600 lb flange,
DN50 PN63
316L SS
ANSI 600 lb
P600R,
P64R
Pressure Transducer Ranges
Pressure Sensor Ranges
(1)
, psia (bara)
Full Scale Operating Pres-
sure
Maximum Over-Range Pressure
psia
(bara)
psia
(bara)
30
2
60
4
100
7
200
14
300
20
600
40
500
35
1000
70
1500
100
2500
175
Note: (1) To maximize accuracy, specify the lowest full scale operat-
ing pressure range for the application. To avoid damage, the
flow meter must never be subjected to pressure above the
over-range pressure shown above.
Power Requirements
12 to 36 VDC, 25 mA, 1 W max., Loop Powered Volumetric or Mass
12 to 36 VDC, 300 mA, 9 W max. Multiparameter Mass options
100 to 240 VAC, 50/60 Hz, 5 W max. Multiparameter Mass
options
Use a Class I (Grounded Type) or Class 2 (double insulated) power
supply.
Installation (Over-voltage) Category II for transient over-voltages
AC & DC Mains supply voltage fluctuations are not to exceed
+/-10% of the rated supply voltage range.
Summary of Contents for Pro-T
Page 10: ...Table of Contents Series M22 M23 M24 Instruction Manual 0 10 M 000 00010...
Page 20: ...Chapter 1 Introduction Series M22 M23 M24 Instruction Manual 1 10 M 000 00010...
Page 60: ...Chapter 2 Installation Series M22 M23 M24 Instruction Manual 2 40 M 000 00010...
Page 126: ...Chapter 5 Troubleshooting Repair Series M22 M23 M24 Instruction Manual 5 16 M 000 00010...
Page 140: ...Appendix B Approvals Series M22 M23 M24 Instruction Manual B 4 M 000 00010...
Page 150: ...Appendix D Glossary Series M22 M23 M24 Instruction Manual D 4 M 000 00010...