Group 28
Troubleshooting
MID 128 SID 24 Rack Position Sensor
D7C only
Fault Codes
FMI 2
Incorrect data.
Conditions for fault code:
•
Unreasonable measurement value from rack posi-
tion sensor.
Possible cause:
•
Sensor value outside measurement range.
•
Open circuit or short circuit in wires.
•
Internal fault in the pump.
•
Faulty sensor.
Reaction from the EECU:
•
Fault code is set.
•
Red lamp is requested.
•
Output for rack drive is switched off.
Noticeable external symptom:
•
Red lamp lights up.
•
The engine stops or does not start.
FMI 13
Sensor values outside calibration values.
Conditions for fault code:
•
Unreasonable measurement value at start-up.
Possible cause:
•
Uncalibrated sensor.
•
Faulty sensor.
Reaction from the EECU:
•
Fault code is set.
•
Red lamp is requested.
•
Output for rack drive actuator is switched off.
Noticeable external symptom:
•
Red lamp lights up.
•
The engine does not start.
174
Summary of Contents for TSI
Page 1: ......
Page 8: ...6...
Page 30: ...Group 28 Specifications Schematic D12B W2002827 28...
Page 31: ...Group 28 Specifications Schematic D12C W2003348 29...
Page 32: ...Group 28 Specifications Schematic D7C W2002826 30...
Page 33: ...Group 28 Specifications Schematic VECU W3003497 31...
Page 34: ...32...
Page 86: ...84...
Page 96: ...Group 28 Troubleshooting 94...
Page 110: ...Group 28 Troubleshooting Fuel Pressure Sensor Pres sure Voltage Chart W2002799 108...
Page 114: ...Group 28 Troubleshooting Oil Pressure Sensor Pres sure Voltage Chart W2002732 112...
Page 118: ...Group 28 Troubleshooting Boost Pressure Sensor Pres sure Voltage Chart W2002730 116...
Page 129: ...Group 28 Troubleshooting Coolant Temperature Sensor Tem perature Resistance Chart W2002729 127...
Page 140: ...Group 28 Troubleshooting Fuel Temperature Sensor Tempera ture Resistance Chart W2002742 138...
Page 144: ...Group 28 Troubleshooting Oil Temperature Sensor Tempera ture Resistance Chart W2002727 142...
Page 248: ......
Page 249: ...Operation Numbers 2841 03 02 01 Engine ECU Replacement 243...