Output interface, 4–20 mA
Output.interface.to.aftermarket.control.systems.that.
support.4–20.mA..No.calibration.is.needed.
-. Slip.function
Installation order (Interface Out)
NOTE!.The.interface.works.at.different.speeds/baud.
rates,.depending.on.whether.it.is.used.as.an.in.or.out.
interface.
Connect.the.Y.connector.(2).between.the.PCU.and.
the.engine,.as.in.the.figure..
Change.the.interface.baud.rate.by.jumpering.Pin.9.
and.Pin.10.on.the.screw.terminal,.as.in.the.figure..
Connect.the.interface.to.the.12-pin.connector.on.the.
Y.connector,.as.in.the.figure..
NOTE!.Fix.the.interface.in.a.suitable.place,.using.a.
tie.wrap.or.screw.
Throttle diode (A):
Constant.light.-..
Input.signal.is.valid,.i.e..between.4–20.mA.
Flashes.(10.Hz).-..
Input.signal.is.<.4.mA.or.>.21.mA.
Switched.off.-..
Other.cases.
Slip diode (B):
Constant.light.-..
Input.signal.for.slip.is.valid,.i.e..between.4-20.mA.
Flashes.(10.Hz).-..
Input.signal.is.<.4.mA.or.>.21.mA.
Switched.off.-..
Other.cases.
NOTE!.Also.applies.to.the.Out.interface.
1
2
PCU
4-20.mA
Gear diode (C):
Constant.light.-.
Input.signal.for.Reverse.or.Forward.is.>.6.V.
Flashes.(10.Hz).-..
Input.signal.for.Reverse.and.Forward.is.>.6.V.(at.the.
same.time).
Switched.off.-..
Other.cases.
Power diode (D):
Constant.light.-..
The.unit.has.power.supply.
Flashes.(1.Hz).-.
No.communication.on.the.CAN.bus.
Flashes.(10.Hz).-..
Communication.on.the.CAN.bus.
Switched.off.-..
Other.cases.