Location and mounting
of the PCU and the HCU
PCU location
Locate.the.PCU.node.in.the.engine.room,.far.from.
heat.sources.and.in.a.dry.and.accessible.place.
HCU location
Alwas.locate.the.HCU.node.in.a.dry.and.accessible.
place.and.close.to.the.helm.station.it.is.serving.
Mounting
The.PCU/HCU.nodes.shall.be.fitted.with.
three
screws.
Cables.shall.be.lead.into.the.PCU/HCU.in.a.way.such.
that.no.water.can.enter.into.the.units.or.the.cable.
harnesses.
The.PCUs.and.HCUs.can.also.be.stacked.through.
slides.on.top.the.nodes..
NOTE!.Maximum.two.units.are.to.be.stacked.
Installation procedure, engine room
NOTE!.The.HCUs.in.a.twin installation.can.be.in-
stalled.with.a.maximum.distance.between.them.of.
approximately.0.8.m.(2.6.ft).as.the.synchronization.
cable.has.a.length.of.1m.(3.ft).
.
IMPORTANT!.Never.mount.the.PCU.and.HCU.
units.with.the.connectors.pointing.upwards.
35