Neutral beep
Vodia.text:."NeutralBIP"..This.parameter.makes.it.
possible.to.activate.or.deactivate.the.fuction.that.
gives.a."beep".sound.when.the.control.lever.is.set.
to.NEUTRAL.position..The.function.is.possible.to.
activate.individually.for.the.helms.(HCUs)..When.the.
function.is.desirable.on.all.helms,.you.have.to.acti-
vate.it.in.the.PCU.by.using.the.VODIA.tool..This.will.
affect.all.helm.stations.in.the.actual.drive.line,.which.
means.up.to.four.possible.HCUs.(per.drive.line).
Activated.for.a.PCU.(MID.187)..
.
Transom angle (drive DPH/DPR)
Vodia.text:."Transom.angle"..This.parameter.is.used.
to.adjust.the.transom.angle.estimated.for.the.boat.
by.the.EVC.system..Adjustment.can.be.done.without.
correcting.the.trim.potentiometer.on.the.drive.shield..
The.potentiometer.is.used.for.powertrim.functions.
and.transmit.information.about.drive.trim.positions.to.
the.EVC.system.
Normal.transom.angle,.that.is.default.value,.is.13°..If.
other.values.are.needed,.the.transom.angle.can.be.
adjusted.between.8°.and.25°.
Activated.for.a.PCU.(MID187)..
.
Lever type
Vodia.text:."Lever.type"..
This.parameter.is.used.when.the.4–20.mA.interface.
is.installed..Values."On"/"Off".."On".shall.be.set.when.
the.IN.interface.is.used.
Activated.for.a.HCU.(MID164).
118
Summary of Contents for EVC EC -C
Page 1: ...EVCEC C Electronic Vessel Control D4 D6 D9 D12 D16 Installation 1 1 B E ...
Page 2: ......
Page 135: ...Notes 135 ...
Page 136: ... References to Service Bulletins Group No Date Concerns 136 ...
Page 138: ...7745547 English 09 2007 ...