44
Capacity
Range
100/120Hz
1kHz
10kHz
100kHz
Resolution
200.00 pF
N/A
N/A
2.0% + 1pF
[1]
2.0% + 1pF
[2]
0.01pF
2000.0 pF
0.5% + 8
[1]
0.5% + 8
[1]
0.5% + 8
[1]
0.5% + 8
0.1pF
20.000 nF
0.5% + 5
0.5% + 5
0.5% + 5
0.5% + 5
0.001nF
200.00 nF
0.5% + 5
0.5% + 5
0.5% + 5
1.0% + 5
0.01nF
2000.0 nF
0.5% + 5
0.5% + 5
1.0% + 5
N/A
0.1nF
20.000 µF
0.5% + 5
1.0% + 5
N/A
N/A
0.001µF
200.00 µF
1.0% + 5
N/A
N/A
N/A
0.01µF
[1] The accuracy is specified after subtraction of the scatter capacities of the measuring
lines.
[2] <50 digit fluctuates
[3] If D > 0.1, the tolerance should be multiplied with
.
Impedance
Range
100/120Hz
1kHz
10kHz
100kHz
Resolution
20.000 Ω
N/A
0.5% + 50
[1]
0.5% + 50
[1]
0.5% + 50
[1]
0.001Ω
200.00 Ω
0.5% + 8
0.5% + 8
0.5% + 8
0.5% + 8
0.01Ω
2.0000 kΩ
0.5% + 5
0.5% + 5
0.5% + 5
0.5% + 5
0.1Ω
20.000 kΩ
0.5% + 5
0.5% + 5
0.5% + 5
1.0% + 5
1Ω
200.00 kΩ
0.5% + 5
0.5% + 5
1.0% + 5
[2]
N/A
10Ω
2.0000 MΩ 0.5% + 5
1.0% + 5
[2]
N/A
N/A
100Ω
20.000 MΩ 1.0% + 5
[2]
N/A
N/A
N/A
1KΩ
[1] The accuracy is indicated by subtraction of the offset impedance.
[2] <50 digit fluctuates
[3] If Q > 0.1, the tolerance should be multiplied with
.