39
c) Measurement of the resistance/impedance
Make sure that all circuit parts, circuits and components and other objects of
measurement are disconnected from the voltage and discharged.
Switch on the meter at the operating button (A).
After switching on, the smart “AUTO LCR” mode is always active. Many settings are done by
the measuring device. Of course, you can also determine the settings manually by pushing the
buttons “L/C/R” (B), “D/Q/θ/ESR” (D), “CAL/Hz” (E) and “Δ/H” (C).
The measuring frequency can be selected with the button “CAL/Hz” (E). The following values
are available: 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz. Every time you press it, the measured
value switches. The measuring frequency also determines the measuring range.
If you want to measure direct current resistance (DCR), select the measuring function “DCR”
via the “D/Q/θ/DCR” (D) button.
Connect the measuring object (e.g. a resistor) to the measuring input. After a short time the
display shows the resistance. Wait until the displayed value has stabilised. This may take
several seconds.