6. oPErATINg ELEmENTS

V

W

A

C.V.

C.C.

POWER

PRESET 1

PRESET 2

PRESET 3

LOCK / UNLOCK

OUTPUT ON/OFF

A / W

SHIFT

V /   

i

MENU

REMOTE

CONTROL

MAIN OUTPUT

REMOTE

PUSH

FINE / COARSE

[ UVL ]

PUSH

FINE / COARSE

[ UCL ]

VOLTAGE

CURRENT

2

1

8

3

4

5

6

7

9

9

1  On / off switch 

PowEr

2  Measuring display element with indicator for 

C.V.

 (Constant voltage) and 

C.C.

 (Constant current)

3  LED remote control display (remote control/ USB mode)
4  Adjusting controller 

VoLTAgE

 (output voltage)

5  Adjusting controller 

CurrENT

 (output voltage)

6  Connector sockets 

mAIN ouTPuT

 (max. 20 A by CPPS-320-42, max. 10 A by CPPS-320-84)

7  USB- connector 

  (for connecting to a computer, for cyclical operation with programmed voltage, current, time and time cycle)
8   Illuminated function buttons (

PrESET 1, 2, 3

 buttons, 

LoCk/uNLoCk

 button (A/W measurement button), 

mENu

 button (SHIFT button), 

ouTPuT oN/off

 button (

ΔV/Δt

 button))

9  Folding feet

US

O

NL

W

IT

XX

XX

 X

XX

X

Remote

Sensing

11

10

12

10  Remote control connection 

remote Control

11  Connector sockets 

remote Sensing

12  Cold device connection and mains fuse

Summary of Contents for CPPS-320-42

Page 1: ...ATING INSTRUCTIONS page 36 68 CPPS 320 42 Alimentation en nergie pour laboratoire automatique F MODE D EMPLOI page 69 102 CPPS 320 42 Automatisch labtransformator O GEBRUIKSAANWIJZING pagINA 103 136 B...

Page 2: ...es Verbrauchers 14 9 Funktionstasten 15 a Tastensperrfunktion 15 b Manueller Ausgang EIN AUS 15 c Einstellbares Amperemeter Wattmeter 15 10 Speicherplatzbetrieb Preset 16 11 V t Funktion 17 a Voreinst...

Page 3: ...18 Schutzeinrichtungen 31 a berspannungsabschaltung 31 b bertemperaturabschaltung 31 c bertemperaturabschaltung 31 19 Wartung und Pflege 32 a Allgemein 32 b Netzsicherung wechseln 32 20 Behebung von...

Page 4: ...arkenfamilie selbst f r die anspruchsvollsten Aufgaben immer die optimale L sung zur Hand Und das Besondere Die ausgereifte Technik und die zuver l ssige Qualit t unserer Voltcraft Produkte bieten wir...

Page 5: ...tiometer 5 kOhm kann die Ausgangsspannung und der Ausgangsstrom eingestellt werden Der DC Ausgang ist ber einen Schaltkontakt ein und ausschaltbar Drei frei programmierbare Speicherpl tze k nnen mit u...

Page 6: ...mit dem Ausrufezeichen im Dreieck weist auf wichtige Hinweise in dieser Bedienungsanlei tung hin die unbedingt zu beachten sind Das Pfeil Symbol ist zu finden wenn Ihnen besondere Tipps und Hinweise z...

Page 7: ...bereits geringer H he wird es besch digt Beachten Sie auch die Sicherheitshinweise und Bedienungsanleitungen der brigen Ger te an die das Produkt angeschlossen wird Produkte die an Netzspannung betri...

Page 8: ...m Kabel aus der Netzsteckdose Unter folgenden Bedingungen muss der Netzstecker aus der Steckdose gezogen werden vor dem Reinigen des Produkts bei Gewitter wenn das Produkt ber einen l ngeren Zeitraum...

Page 9: ...hluss des Produktes haben Lassen Sie Wartungs Anpassungs und Reparaturarbeiten ausschlie lich von einem Fachmann bzw einer Fachwerkstatt durchf hren Sollten Sie noch Fragen haben die in dieser Bedienu...

Page 10: ...Ausgangsspannung 5 Einstellregler CURRENT Ausgangsstrom 6 Anschlussbuchsen MAIN OUTPUT max 20 A bei CPPS 320 42 max 10 A bei CPPS 320 84 7 USB Anschluss f r den Anschluss an einen Computer f r den zy...

Page 11: ...er abzuspeichern Auf einen ausreichenden Leiterquerschnitt der DC Anschlussleitungen ist unbedingt zu achten da eine berlastung zum Leitungsbrand f hren kann a Anschluss des Netzkabels 1 Verbinden Sie...

Page 12: ...ie Wahl des Speicherplatzes erfolgt ber die Auswahltasten PRESET 1 2 3 8 und Einstellungen ber die Einstellregler 4 5 Remote Ctrl Fernsteuerbetrieb Das Netzger t kann ber eine externe Spannung oder ei...

Page 13: ...lb von 2 Sekunden keine Einstellung schaltet die Anzeige wieder zur aktuellen Stromanzeige zur ck 5 Zum Einstellen der Strombegrenzung drehen Sie den Einstellregler nach links oder rechts Dies wird du...

Page 14: ...se blanken Stellen sind durch geeignete schwer entflammbare Isolierstoffe oder andere Ma nahmen abzudecken und vor direkter Ber hrung und Kurzschluss zu sch tzen Achten Sie auf einen ausreichenden Lei...

Page 15: ...stasten Drehregler auf der Ger tevorderseite gesperrt sind b Manueller Ausgang EIN AUS 1 Dr cken Sie die Taste OUTPUT ON OFF um den Ausgang manuell ein auszuschalten 2 Die Taste OUTPUT ON OFF leuchtet...

Page 16: ...stellten Werte werden in der Anzeige 2 angezeigt 2 Sie k nnen die voreingestellten Spannungs und Stromwerte entsprechend Ihrer Anwendung ver ndern Die Ausgangsspannung kann am Einstellregler VOLTAGE 4...

Page 17: ...ET Taste um den Einstellmodus zu verlassen Die Taste erlischt b Einstellung der V t Werte 1 Dr cken und halten Sie die Taste MENU 8 f r ca 3 Sekunden gedr ckt 2 Drehen Sie den Einstellregler VOLTAGE 4...

Page 18: ...LTAGE 4 um in den Einstellmodus zu gelangen 4 Drehen Sie den Einstellregler VOLTAGE 4 bis folgende Anzeige erscheint 5 Drehen Sie jetzt den Einstellregler CURRENT 5 bis folgende Anzeige erscheint 6 Dr...

Page 19: ...chlie end den Einstellregler VOLTAGE 4 um in den Einstellmodus zu gelangen 4 W hlen Sie die gew nschte Funktion A B oder C aus und stellen Sie mit dem Einstellregler CURRENT 5 die gew nschte Zeitspann...

Page 20: ...NC A 3 Sekunden FUNC B 3 Sekunden 1 Um die Wellenform zu generieren dr cken Sie die Taste SHIFT 8 und anschlie end die Taste V t 8 2 Die Wellenform wird periodisch erzeugt 3 Dr cken Sie die Taste SHIF...

Page 21: ...und nehmen mit einer kleinen Drehbewegung die vordere schwarze Kontaktbuchse heraus 2 F hren Sie von hinten durch die Metallh lse f nf Anschlussleitungen mit einem Leiterquerschnitt von mindes tens 0...

Page 22: ...Fernbedienungsmodus aktiviert wurde werden alle beleuchteten Funktionstasten 8 gesperrt Die Taste LOCK UNLOCK 8 und die LED Fernbedienungsanzeige 3 leuchten auf 9 Um den Fernbedienungsmodus zu deaktiv...

Page 23: ...Widerstandes Die Anschl sse 1 und 4 d rfen nicht kurzgeschlossen werden d Ausgang fernsteuern Ein Aus Der DC Ausgang kann ber einen Schaltkontakt ein und ausgeschaltet werden Zum Anschluss gehen Sie...

Page 24: ...um in den Einstellmodus zu gelangen 4 Drehen Sie den Einstellregler CURRENT 5 in der rechten Anzeige erscheint yes oder no ja oder nein 5 W hlen Sie yes und dr cken anschlie end den Einstellregler VO...

Page 25: ...zum Verbraucher Achten Sie auf richtige Polarit t Dr cken Sie an den r ckseitigen Anschlussbuchsen Remote Sensing 11 die Klemmenentriegelung mit einem kleinen Schraubendreher nach innen und stecken di...

Page 26: ...G MIT PC SOFTWARE 1 Schlie en Sie das Netzger t mit Hilfe des USB Kabels an eine freie USB Schnittstelle Ihres PCs an Verbinden Sie das mitgelieferte USB Kabel mit der USB Buchse 7 2 Schalten Sie das...

Page 27: ...taste auf Supply Connect und dann auf Single Folgendes Fenster erscheint 6 Klicken Sie auf Setting Folgende Ansicht erscheint 7 Stellen Sie den V I Bereich ein Im folgenden Aufklappmen kann die Datalo...

Page 28: ...28 Beispiel 1 der Vorschau auf die Wellenform Beispiel 2 der Vorschau auf die Wellenform...

Page 29: ...29 Beispiel 3 der Vorschau auf die Wellenform...

Page 30: ...Clear Table um alle Werte in der Tabelle zu l schen 2 Geben Sie die gew nschten Werte in die Tabelle ein Sie k nnen mit den Pfeiltasten auf der Tastatur die jeweili gen Zellen in der Tabelle ausw hlen...

Page 31: ...el f r die Abschaltung sind in den technischen Daten angegeben b bertemperaturabschaltung Der integrierte Temperaturf hler hat eine zu hohe Systemtemperatur festgestellt Um eine berhitzung zu verhinde...

Page 32: ...ie r ckseitige Netzsicherung 12 defekt Befolgen Sie die nachstehenden Schritte um die Hauptsicherung auszutauschen 1 Schalten Sie das Netzger t aus und entfernen alle Anschluss kabel und den Netzsteck...

Page 33: ...Kontrollanzeige REMOTE leuchtet Das Ger t kann ber die Drehregler nicht bedient werden Der Fernsteuerbetrieb ist aktiv Die LED Kontrollleuchte C C leuchtet Konstantstrombetrieb Die voreingestellte St...

Page 34: ...elevanten Vorschriften der Richtlinie 1999 5 EG befindet Die Konformit tserkl rung zu diesem Produkt finden Sie unter www conrad com 22 Entsorgung Elektronische Ger te sind Wertstoffe und geh ren nich...

Page 35: ...nderung 50 mA Strom Regelverhalten bei Netzschwankung 90 264 V AC 10 mA Anzeigegenauigkeit 0 2 5 counts V A Wirkungsgrad 85 Taktfrequenz 44 bis 55 kHz Leistungsfaktor mit aktiver PFC 0 9 Ger tel fter...

Page 36: ...cting a consumer 47 9 Function buttons 48 a Key lock function 48 b Manual output ON OFF 48 c Adjustable ammeter watt meter 48 10 PRESET memory location operation 49 11 V t Function 50 a Presetting the...

Page 37: ...Protective measures 64 a Over voltage protection 64 b Overheating protection 64 c Overload protection 64 19 Maintenance and cleaning 65 a General 65 b Exchanging the fuse 65 20 Troubleshooting 66 21 D...

Page 38: ...craft brand family provide the optimum solution even for the most demanding tasks And the remarkable feature is we offer you the mature technology and reliable quality of our Voltcraft products at an...

Page 39: ...tage and the output current can be set via an external voltage 0 5 V DC or an external potentiometer 5 kOhm The DC output is switched on and off via a switching contact Three freely programmed storage...

Page 40: ...ol with an exclamation mark in a triangle indicates important instructions contained in these operating instructions that must be followed The arrow symbol alerts the user to the presence of important...

Page 41: ...roduct carefully Jolts impacts or a fall even from a low height can damage the product Also observe the safety and operating instructions of any other devices which are connected to the product Produc...

Page 42: ...ilation of the product during operation Do not cover the ventilation ope nings with magazines covers curtains Maintain a minimum distance of 15 cm from the other objects When setting up the product ma...

Page 43: ...roller VOLTAGE output voltage 5 Adjusting controller CURRENT output voltage 6 Connector sockets MAIN OUTPUT max 20 A by CPPS 320 42 max 10 A by CPPS 320 84 7 USB connector for connecting to a computer...

Page 44: ...ction of the DC connection lines since an overload can lead to cable fire a Connecting the power cable 1 Connect the protective contact power cable provided to the cold device connection 12 at the pow...

Page 45: ...tion is made via the PRESET 1 2 3 selection buttons 8 and the settings via the 4 5 setting controller Remote Ctrl Remote control The power supply can be remote controlled via an external voltage or an...

Page 46: ...k to the current power display if a setting is not made within 2 seconds 5 Turn the setting controller to the left or right to set the current limitation This is represented by a slightly lighter digi...

Page 47: ...l these blank points should be covered with suitable flame resistant insulating material or other measu res and protected from direct contact and short circuits Please ensure a sufficient conductor cr...

Page 48: ...all function buttons control dials on the front of the device are blocked b Manual output ON OFF 1 Press the OUTPUT ON OFF button to manually switch the output on off 2 The OUTPUT ON OFF button light...

Page 49: ...on PRESET 1 2 3 8 The button lights up and the preset values are indicated in the display 2 2 You can change the preset voltage and current values according to your needs The output voltage can be cha...

Page 50: ...utton to leave the setting mode The button is no longer illuminated b Setting the V value 1 Press and hold the MENU 8 button for approximately 3 seconds 2 Turn the VOLTAGE 4 setting controller until t...

Page 51: ...ng controller VOLTAGE 4 to reach the setting mode 4 Turn the setting controller VOLTAGE 4 until the following display appears 5 Turn the setting controller CURRENT 5 until the following display appear...

Page 52: ...he following display appears 3 Then press the setting controller VOLTAGE 4 to reach the setting mode 4 Select the function A B or C and turn the setting controller CURRENT 5 to set the time period 0 t...

Page 53: ...onds t b a 3 seconds FUNC A 3 seconds FUNC B 3 seconds 1 To generate the waveform press the SHIFT 8 button then the V t 8 button 2 The waveform will be periodically generated 3 To stop generating the...

Page 54: ...socket and remove the front black contact socket with a small turning movement 2 Insert five connection lines with a cable cross section of at least 0 34 mm2 from behind through the metal sleeves Car...

Page 55: ...he remote control mode was activated The LOCK UNLOCK 8 button and the LED remote control display 3 light up 9 To deactivate the remote control mode press the LOCK UNLOCK 8 button to activate all funct...

Page 56: ...ction 4 at the second end of the resistor The connections 1 and 4 should not be short circuited d Output remote control on off The DC output can be switched on and off via a switch contact Proceed as...

Page 57: ...etting controller VOLTAGE 4 to reach the setting mode 4 Turn the CURRENT 5 setting controller Yes or No appears in the right display 5 Select Yes and then press the setting controller VOLTAGE 4 to con...

Page 58: ...nes of the power supply to the consumer Please note the correct polarity Press the terminal release inside with a small screw driver on the rear connection sockets Remote Sensing 11 and stick the cabl...

Page 59: ...17 CONTROL WITH PC SOFTWARE 1 Connect the power supply to a free USB interface of your PC using the USB cable Connect the USB cable supplied to the USB socket 7 2 Switch on the power supply 3 Start t...

Page 60: ...ft mouse button on Supply Connect and then Single The following window appears 6 Click on Setting The following view appears 7 Set the V I range In the following drop down menu the datalogger sampling...

Page 61: ...61 Example 1 of the preview of the waveform Example 2 of the preview of the waveform...

Page 62: ...62 Example 3 of the preview of the waveform...

Page 63: ...on Clear Table to clear all values in the table 2 Enter data in the table You can use the arrow keys of your keyboard to select the cells in the table Data exceed the rated voltage current will not be...

Page 64: ...s switched off The current levels for switching off are listed in the technical data b Overheating protection The integrated temperature sensor determined that the system temperature is too high To pr...

Page 65: ...possible to switch on the laboratory power unit the rear mains fuse 11 is probably defective Proceed as follows to replace the mains fuse 1 Switch off the power unit and remove all the connection cabl...

Page 66: ...is lit The device can not be operated via the rotary controls Remote control operation is active The control indicator C C is lit Constant current operation The preset current was exceeded Check power...

Page 67: ...s of the directive 1999 5 EC The Declaration of Conformity for this product can be found at www conrad com 22 DISPOSAL Electronic devices are recyclable waste and must not be disposed of in the househ...

Page 68: ...nse at 10 90 load change 50 mA Current control response at mains fluctuation 90 264 V AC 10 mA Display accuracy 0 2 5 counts V A Degree of effectiveness 85 Clock signal 44 to 55 kHz Performance factor...

Page 69: ...mateur 81 9 Touches de fonctionnement 82 a Fonction de verrouillage des touches 82 b Sortie manuelle MARCHE ARR T 82 c Amp rem tre wattm tre r glable 82 10 Fonctionnement espace m moire PRESET 83 11 F...

Page 70: ...ise hors tension en cas de surtension 98 b Mise hors tension en cas de surchauffe 98 c Mise hors tension en cas de surcharge 98 19 Entretien et nettoyage 99 a G n ral 99 b Remplacement du fusible de s...

Page 71: ...oisir un appareil r pondant aux t ches les plus exigeantes et d avoir toujours port e de main la solution optimale Et le meilleur la technologie avanc e et la qualit fiable de nos produits Voltcraft q...

Page 72: ...sion de sortie et le courant de sortie est r gl via une tension externe 0 5 V CC ou via un potentiom tre externe 5 kOhm La sortie CC est activ e et d sactiv e via le contact de commutation Trois espac...

Page 73: ...e Dans ce mode d emploi le symbole avec le point d exclamation dans un triangle indique des instructions importantes qui doivent tre respect es Le symbole fl che est utilis pour pointer certains conse...

Page 74: ...ns des conditions tr s rudes Manipulez le produit avec pr caution la suite de chocs de coups ou de chutes m me de faible hauteur l appareil peut tre endommag Respecter galement les informations concer...

Page 75: ...sible Si le cordon d alimentation est endommag ne le touchez pas Mettez tout d abord la prise de courant correspondante hors tension par ex au moyen du coupe circuit automatique correspondant puis ret...

Page 76: ...nsformateurs etc ou champs lectrostatiques L appareil ne doit pas tre imm diatement connect apr s son transport d un endroit froid vers un environnement chaud La condensation pourrait endommager l app...

Page 77: ...sion de sortie 5 Bouton de r glage CURRENT courant de sortie 6 Bornes de connexion MAIN OUTPUT max 20 A CPPS 320 42 max 10 A CPPS 320 84 7 Port USB pour la connexion un ordinateur pour le fonctionneme...

Page 78: ...lez ce que les fils de raccordement DC disposent d une section de conducteur suffisante car une surcharge peut provoquer un incendie des fils a Raccordement du c ble secteur 1 Branchez le c ble secteu...

Page 79: ...eset La s lection de l espace m moire s effectue via les touches de s lection PRESET 1 2 3 8 et les r glages via les boutons de r glage 4 5 Remote Ctrl Fonctionnement distance le bloc d alimentation p...

Page 80: ...che Si aucun r glage n est effectu dans les 2 secondes l affichage retourne l affichage du courant actuel 5 Pour r gler la limitation de courant tournez le bouton de r glage gauche ou droite Elle est...

Page 81: ...ques d nud s Tous ces endroits d nud s doivent tre recouverts de mat riaux isolants appropri s et difficilement inflammables ou prenez toute autre mesure afin de vous prot gez contre les contacts dire...

Page 82: ...UNLOCK s allume lorsque toutes les touches de fonction boutons de r glage sont d sac tiv es sur la fa ade de l appareil b Sortie manuelle MARCHE ARR T 1 Appuyez sur la touche OUTPUT ON OFF pour allume...

Page 83: ...urs pr r gl es sont affich es sur l cran d affichage 2 2 Selon votre application vous pouvez modifier les valeurs actuelles pr r gl es de la tension et du courant La tension de sortie peut tre modifi...

Page 84: ...la touche PRESET correspondante La touche s teint b R glage des valeurs V t 1 Appuyez et maintenez la touche MENU 8 pendant env 3 secondes 2 Tournez le bouton de r glage VOLTAGE 4 jusqu ce que l affic...

Page 85: ...GE 4 pour acc der au mode de r glage 4 Tournez le bouton de r glage VOLTAGE 4 jusqu ce que l affichage suivant apparaisse 5 Tournez le bouton de r glage CURRENT 5 jusqu ce que l affichage suivant appa...

Page 86: ...Appuyez ensuite sur le bouton de r glage VOLTAGE 4 pour acc der au mode de r glage 4 S lectionnez la fonction A B ou C et ajuster avec le bouton de r glage CURRENT 5 la p riode de rattrapage requis de...

Page 87: ...secondes FUNC B 3 secondes 1 Pour g n rer la forme d onde appuyez sur la touche SHIFT 8 et appuyez sur la touche V t 8 2 La forme d onde est g n r p riodiquement 3 Appuyez sur la touche SHIFT 8 et ap...

Page 88: ...commande Remote et enlevez avec un petit mouvement de rotati on le connecteur de contact noir avant 2 Introduisez par l arri re cinq c bles de raccordement avec une section du conducteur d au moins 0...

Page 89: ...hes de fonction lumineuses 8 sont d termi n es La touche LOCK UNLOCK 8 et le voyant LED de contr le distance 3 s allument 9 Pour d sactiver le mode de commande distance appuyez sur la touche LOCK UNLO...

Page 90: ...extr mit de la r sistance Les bornes 1 et 4 ne doivent pas tre court circuit es d Commande distance de la sortie marche arr t La sortie DC peut tre activ e et d sactiv e par un contact de commutation...

Page 91: ...glage VOLTAGE 4 pour acc der au mode de r glage 4 Tournez le bouton de r glage CURRENT 5 afin que l affichage droite indique yes ou no oui ou non 5 S lectionnez yes et appuyez ensuite sur le bouton d...

Page 92: ...er les c bles d alimentation du bloc d alimentation au consommateur Respectez bien la polarit Avec un petit tournevis appuyez sur le d blocage des terminaux des bornes de raccordement Remote Sensing 1...

Page 93: ...via un logiciel sur PC 1 Branchez le bloc d alimentation l aide du c ble USB sur une interface USB disponible de votre PC Branchez le c ble USB fourni au port USB 7 2 Allumez le bloc d alimentation 3...

Page 94: ...n gauche de la souris sur Supply Connect puis Single L affichage suivant appara t 6 Cliquez sur Setting L affichage suivant appara t 7 R glez le V I port e La suite menu pop up la fr quence d chantill...

Page 95: ...95 Exemple 1 de l aper u de la forme d onde Exemple 2 de l aper u de la forme d onde...

Page 96: ...96 Exemple 3 de l aper u de la forme d onde...

Page 97: ...tes les valeurs dans le tableau 2 Entrez les valeurs souhait es dans le tableau Vous pouvez utiliser les touches fl ch es du clavier les cellules respectives dans le tableau Les valeurs qui d passent...

Page 98: ...aux de tension pour les mises hors circuit sont indiqu s dans les donn es tech niques b Mise hors tension en cas de surchauffe La sonde de temp rature int gr e a d tect une temp rature syst me trop le...

Page 99: ...secteur 11 soit d fectueux Afin de remplacer le fusible de secteur proc dez comme suit 1 D sactivez l alimentation et d branchez tous les c bles de raccordement et le cordon secteur de l appareil 2 A...

Page 100: ...pas tre command par le r gulateur Le fonctionnement distance est activ L indicateur C C s allume Fonctionnement courant constant L intensit de courant pr r gl e a t d pass e V rifiez la con sommation...

Page 101: ...rective 1999 5 CE La d claration de conformit DOC de cet appareil peut tre consult e sur le site www conrad com 22 limination des d chets Les appareils lectroniques sont des d chets recyclables et ne...

Page 102: ...charge 50 mA Mode de r gulation de courant Variation de r seau 170 264 V CA 10 mA Pr cision d affichage 0 2 5 counts V A Rayon d action 85 Fr quence de base 44 55 kHz Facteur de rendement PFC actif 0...

Page 103: ...gsadapter 115 9 Functietoetsen 116 a Toetsenblokkering 116 b Handmatige output AAN UIT 116 c Regelbare amp re wattmeter 116 10 Gebruik als Preset geheugen 117 11 V t functie 118 a Het voorprogrammeren...

Page 104: ...132 a Uitschakeling bij overspanning 132 b Uitschakeling bij oververhitting 132 c Uitschakeling bij overbelasting 132 19 Onderhoud en reiniging 133 a Algemeen 133 b Netzekering vervangen 133 20 Verhe...

Page 105: ...raft assortiment zelfs voor de meest veeleisende opgaven altijd de beste oplossing tot zijn beschikking En wat heel bijzonder is De uitgekristalliseerde techniek en de betrouwbare kwaliteit van onze V...

Page 106: ...age 0 5 V DC of via een externe potenti ometer 5 kOhm kunnen outputvoltage en outputstroom ingesteld worden De DC output wordt aan en uitgezet via een schakelcontact Er zijn drie programmeerbare prese...

Page 107: ...che schok Het symbool met het uitroepteken in een driehoek wijst op belangrijke tips in deze gebruiksaanwijzing die beslist opgevolgd moeten worden Het pijlsymbool geeft aan dat er bijzondere tips en...

Page 108: ...ngunstige omstandigheden of onderhevig geweest is aan ernstige transportdruk Behandel het product met zorg Schokken botsingen of zelfs een val van beperkte hoogte kan het product beschadigen Neem ook...

Page 109: ...t Gebruik het product in geen geval met een beschadigd netsnoer Vervang een beschadigd netsnoer door een nieuw netsnoer van hetzelfde type Stekkers mogen nooit met natte handen in de contactdoos worde...

Page 110: ...r heeft aangepast b Overige Raadpleeg een expert wanneer u twijfelt over het juiste gebruik de veiligheid of het aansluiten van het product Onderhoud aanpassingen en reparaties mogen alleen uitgevoerd...

Page 111: ...AGE instelknop outputvoltage 5 CURRENT instelknop outputstroom 6 MAIN OUTPUT aansluitstekkerbussen max 20 A bei CPPS 320 42 max 10 A bij CPPS 320 84 7 USB poort voor aansluiting op een computer voor c...

Page 112: ...telde parameters op te slaan Het is essentieel te zorgen voor voldoende leidingdoorsnede van de DC aansluitbekabeling omdat dit kan leiden tot overbelasting van en brand in de leiding a Het netsnoer a...

Page 113: ...t geheugen verloopt via de selectietoetsen PRESET 1 2 3 8 en instellingen via de instelknoppen 4 5 Remote Ctrl Gebruik via afstandsbediening De voedingsadapter kan op afstand bediend worden via extern...

Page 114: ...nstelling dan keert het display terug naar de huidige stroom weergave 5 Om de stroombegrenzing in te stellen draait u de instelknop naar links of naar rechts Dit wordt aangegeven d m v een enigszins h...

Page 115: ...erde bekabeling en contacten moet vermeden worden Alle onge soleerde plekken moe ten afgedekt worden met geschikte vlambestendige isolatiematerialen of andere beschermende maatregelen tegen direct con...

Page 116: ...ctie en draaiknoppen op het voorpaneel vergrendeld zijn b Handmatige output AAN UIT 1 Druk op de OUTPUT ON OFF toets om de output handmatig aan of uit te zetten 2 De OUTPUT ON OFF toets licht op wanne...

Page 117: ...grammeerde waarden worden in het display 2 weergegeven 2 U kunt de voorgeprogrammeerde voltage en stroomwaarden naargelang uw toepassing wijzigen Het outputvol tage kan via de VOLTAGE knop 4 ingesteld...

Page 118: ...ts om de instelmodus te verlaten De toetsverlichting gaat uit b Instellen van de V t waarde 1 Houd de MENU toets 8 gedurende ca 3 seconden ingedrukt 2 Draai aan de VOLTAGE instelknop 4 tot het volgend...

Page 119: ...nop 4 om in de instelmodus te komen 4 Draai aan de VOLTAGE instelknop 4 tot het volgende op het display verschijnt 5 Draai dan aan de CURRENT instelknop 5 tot het volgende op het display verschijnt 6...

Page 120: ...lay verschijnt 3 Druk vervolgens op de VOLTAGE instelknop 4 om in de instelmodus te komen 4 Selecteer de gewenste functie A B of C Drai de CURRENT instelknop 5 om de periode in te stellen van 0 tot 60...

Page 121: ...3 seconden FUNC A 3 seconden FUNC B 3 seconden 1 Om de golfvorm te genereren druk op SHIFT toets 8 en druk daarna op V t toets 8 2 De golfvorm is periodiek gegenereerd 3 Tot de generatie van de golfv...

Page 122: ...der de schroef aan de zijkant van de meegeleverde stekkerbus van de aansluiting voor de afstandsbedie ning Neem er daarna met een kleine draaibeweging de voorste zwarte contactbus uit 2 Voer langs de...

Page 123: ...chte functietoetsen 8 vastgelegd De LOCK UNLOCK toets 8 en de LED weergave van de afstandsbediening 3 lichten op 9 Om de afstandsbedieningsmodus te deactiveren drukt u eerst op de LOCK UNLOCK toets 8...

Page 124: ...ansluiting 4 op het tweede uiteinde van de weerstand Aansluitingen 1 en 4 mogen niet kortgesloten worden d Output van de afstandsbediening aan uit De DC output wordt aan en uitgezet via een schakelcon...

Page 125: ...OLTAGE instelknop 4 om in de instelmodus te komen 4 Draai aan de CURRENT instelknop 5 In het rechter display verschijnt nu yes or no ja of nee 5 Selecteer yes en druk vervolgens op de VOLTAGE instelkn...

Page 126: ...de voedingsadapter aan op het externe apparaat Zorg voor de juiste polariteit Druk de terminalvrijgave van de aansluitstekkerbussen aan de achterzijde van de Remote Sensing 11 met een kleine schroeve...

Page 127: ...ng met pc software 1 Sluit de voedingsadapter via de USB kabel aan op een vrije USB poort van uw PC Sluit de meegeleverde USB kabel aan op de USB stekkerbus 7 2 Zet de voedingsadapter aan 3 Start het...

Page 128: ...sknop op Supply Connect en vervolgens op Single De volgende weergave verschijnt 6 Klik op Setting De volgende weergave verschijnt 7 Stel de V I vari ren Het volgende pop up menu kan de bemonsteringsfr...

Page 129: ...129 Voorbeeld 1 van de preview van de golfvorm Voorbeeld 2 van de preview van de golfvorm...

Page 130: ...130 Voorbeeld 3 van de preview van de golfvorm...

Page 131: ...op Clear Table om alle waarden in de tabel te wissen 2 Voer de gewenste waarden in de tabel U kunt de pijltjestoetsen op het toetsenbord de respectieve cellen in de tabel Waarden die de nominale spann...

Page 132: ...wordt uitgeschakeld Het spanningsniveau voor de uitschakeling zijn in de techn gegevens vermeld b Uitschakeling bij oververhitting De ge ntegreerde temperatuursensor heeft een te hoge systeemtemperat...

Page 133: ...n werd waarschijnlijk de netbeveiliging aan de achterzijde 11 geactiveerd Voor het vervangen van de netzekering gaat u als volgt te werk 1 Schakel de netvoeding uit en verwijder alle aansluitsnoeren e...

Page 134: ...den bediend met de draaiknoppen De werking met afstandsbediening is geactiveerd De controlelamp C C brandt Constante stroomwerking De vooringestelde stroomsterkte werd overschreden Controleer de stroo...

Page 135: ...1999 5 EG voldoet De bij dit product behorende verklaring van conformiteit kunt u vinden op www conrad com 22 verwijdering Elektronische apparaten zijn recyclebare stoffen en horen niet bij het huisv...

Page 136: ...Stroom Regeling bij netinstabiliteit 170 264 V AC 10 mA Weergavenauwkeurigheid 0 2 5 counts V A Rendement 85 Klokfrequentie 44 tot 55 kHz Arbeidsfactor met aktieve PFC 0 9 Toestelventilator Temperatu...

Page 137: ...137...

Page 138: ...138...

Page 139: ...139...

Page 140: ...t the time of printing Copyright 2015 by Conrad Electronic SE F Information l gales Ceci est une publication de Conrad Electronic SE Klaus Conrad Str 1 D 92240 Hirschau www conrad com Tous droits r se...

Reviews: