52
12. A/b/C fuNCTIoN ANd CurVE gENErATor
The A/B/C function determines the duration (0 to 600 seconds) for which the respective voltage source A/B/C
remains active before it moves to the next voltage source.
Before setting the A/B/C function first enter the ΔV/Δt value (→ chapter 11 b).
1. Press and hold the
mENu
(8) button for approx. 3 seconds.
2. Turn the setting controller
VoLTAgE
(4) until the following display appears:
3. Then press the setting controller
VoLTAgE
(4) to reach the setting mode.
4. Select the function A, B or C and turn the setting controller
CurrENT
(5) to set the time period (0 to 600 se-
conds).
Example 1:
Pulse waveform with 3 seconds at 10 V and 1 second at 5 V
• A (PRESET 1) = 5 V
• B (PRESET 2) = 10 V
• FUNC A = 1 second
• FUNC B = 3 seconds
• Δt a-b = 0
• Δt b-a = 0
1. To generate the waveform, press the
ShIfT
(8) button, then the
ΔV/Δt
(8) button.
2. The waveform will be periodically generated.
3. To stop generating the waveform press
ShIfT
(8) button, then the
ΔV/Δt
(8) button.
B = 10 V
A = 5 V
3 s
1 s
Summary of Contents for CPPS-320-42
Page 28: ...28 Beispiel 1 der Vorschau auf die Wellenform Beispiel 2 der Vorschau auf die Wellenform...
Page 29: ...29 Beispiel 3 der Vorschau auf die Wellenform...
Page 61: ...61 Example 1 of the preview of the waveform Example 2 of the preview of the waveform...
Page 62: ...62 Example 3 of the preview of the waveform...
Page 95: ...95 Exemple 1 de l aper u de la forme d onde Exemple 2 de l aper u de la forme d onde...
Page 96: ...96 Exemple 3 de l aper u de la forme d onde...
Page 129: ...129 Voorbeeld 1 van de preview van de golfvorm Voorbeeld 2 van de preview van de golfvorm...
Page 130: ...130 Voorbeeld 3 van de preview van de golfvorm...
Page 137: ...137...
Page 138: ...138...
Page 139: ...139...