10
MAINTENANCE
Mod. PAGURO
6000/9000/14000/18000/6500/8500
Date: 12.03.2020_Rev: 0.0
9
Clogged fuel filter;
Replace.
8
Low engine oil pressure.
Oil pump worn.
Replace.
Adjustment valve not
registered.
Record.
9
Noisy generator
Damaged bearings.
Replace.
Loose coupling.
Check and repair.
10
Fluid leaks found.
Loose lines or fittings.
Position and tighten properly.
Faulty lines or fittings.
Replace. Contact Technical
Support.
11
High cooling water
temperature.
Thermostat defective
Replace.
Dirty tube nest.
Clean.
Worn seawater pump
impeller.
Replace.
Blocked lines.
Check and release.
12
The generator makes an
unusual noise.
Mechanical parts or
components of the generator
may be loose or faulty.
If the problem persists, contact
Technical assistance.
Exhaust system fault.
Shut down the generator
immediately, inspect the system,
and contact Technical Support if
necessary.
13
Excessive vibration.
Mechanical parts or
components of the generator
may be loose or faulty.
If the problem persists, contact
Technical assistance.