5.8.3 Transfer switch over shore line / generator line
It must be absolutely avoided that the shore line and the generator remain contemporaneously connected to
the boat plant.
A manual switch (shore / generator) or an automatic switch (shore / generator) must be provided.
Both the lines or at least the generator line only, have to be protected with a thermo-switch, fitted on
the main board panel. For your PAGURO choose a:
230V
115V
PAGURO 6000
25A
63A
PAGURO 9000
40A
80A
PAGURO 14000
63A
125A
PAGURO 18000
80A
125A
PAGURO 6500
25A
80A
PAGURO 8500
40A
80A