10
MAINTENANCE
Mod. PAGURO
6000/9000/14000/18000/6500/8500
Date: 12.03.2020_Rev: 0.0
14
WARNING! Sulfuric acid in lead batteries can cause severe burns on skin and damage clothing. Wear
protective gear.
WARNING! Wear rubber gloves, a rubber apron and eye protection when servicing batteries. Lead acid
batteries emit hydrogen, a highly explosive gas, which can be ignited by electrical arcing or a lighted
cigarette, cigar or pipe. Do not smoke or allow an open flame near the battery being serviced. Shut off
all electrical equipment in the vicinity to prevent electrical arcing during servicing.
Switch off any electrical equipment near the batteries in order to avoid ignition sources of
flames/sparks during maintenance.
10.5.9 Endothermic engine maintenance
Refer to the procedures in Attachment 1A for all other endothermic engine maintenance information not listed
in this manual.
10.6 STORAGE OF THE GENERATOR
If the generator is to be stored for 1 to 6 months, carry out the following operations:
– Drain seawater from the pump;
– Close the engine exhaust and intake properly with adhesive tape.
– Replace oil and the engine oil filter.
– Replace the fuel filter;
– Cover the generator with a nylon cloth and place it on a wooden floor.
NOTE: For storage more than 6 months please contact the Manufacturer
VTE S.r.l.