Instruction Manual
Voith Turbo
I/H Converter DSG-BXX112
I/H Converter DSG-BXX102
09 / 03 cet - Ochs/ZAN1
Voith Turbo GmbH & Co, KG
Page: 4 / 21
3.626 - 018877 en
D – 74564 Crailsheim
1.
Technical Data
Ambient conditions:
Ambient temperature for storage
-40
°
C ... +90
°
C
Ambient temperature
-20 °C …+85 °C
Protection
IP 65 to EN 60529
suitable for internal installation in industrial air
Electric data:
Supply voltage
24 VDC
±
15%
Power consumption
approx. 0.7 A
max. 3 A, for t
<
1 sec
Setpoint input
w = 0/4...20 mA
input resistor 25 Ohm
with suppressor circuit
Hydraulic data:
Input pressure P
in
min
1.5 bar more than P
A
max
Input pressure P
in
max
see table
Pressure fluid
mineral oil or hydraulic oil (hardly
combustible fluids on request)
Viscosity pressure fluid
ISO VG 32... ISO VG 48 to
DIN 51519
Temperature pressure fluid
+10
°
C...+70
°
C
Oil purity
recommended purity class:
To NAS1638 class 7
To ISO4406 class -/16/13
Leakage
£
5 l/min