Instruction Manual
Voith Turbo
I/H Converter DSG-BXX112
I/H Converter DSG-BXX102
09 / 03 cet - Ochs/ZAN1
Voith Turbo GmbH & Co, KG
Page: 15 / 21
3.626 - 018877 en
D – 74564 Crailsheim
During the test run, check all hydraulic connections for leakages. In
case of leakage, immediately switch off the hydraulic supply and
eliminate leakages.
6.2
Parameter setting
Due to unintentional maladjustment of the parameters or changed
operating conditions, new setting of one or both parameters may become
necessary.
We recommend to document adjustment of the parameters as well as the
set values.
The parameters are adjusted by means of potentiometers X0 and X1.
Please refer to chapter 10 for the position of the potentiometers.
Potentiometer effects:
X0 -
With help of potentiometer X0 the minimum output pressure
P
A
min is adjusted at a setpoint of 0 mA or 4 mA.
Pressure increase by turning the potentiometer clockwise.
X1 -
With help of potentiometer X1 the maximum output pressure
P
A
max is adjusted at a setpoint of 20 mA.
Pressure increase by turning the potentiometer clockwise
X1 should be adjusted before X0.
The X1- adjustment influences the adjustment of X0.
Manufacturer-provided adjustments:
At the works, the
I/H converter has been adjusted as indicated in the
order.