Instruction Manual
Voith Turbo
I/H Converter DSG-BXX112
I/H Converter DSG-BXX102
09 / 03 cet - Ochs/ZAN1
Voith Turbo GmbH & Co, KG
Page: 19 / 21
3.626 - 018877 en
D – 74564 Crailsheim
Inspection after approx. 740 operating hours / max. 1 month
Take an oil sample from the oil tank and analyse it for solid and
suspended matters, water content, shadings and air bubbles.
Analyse oil purity of the oil sample. Clean or exchange the oil, if
required, in an appropriate operating mode.
Inspection after approx. 8000 operating hours / max. 1 year
Take an oil sample from the oil tank and analyse it chemically.
If required, clean or change the oil during an appropriate operating mode.
Check and retighten, if necessary, the electric connections of the I/H
converter.
9.
Shutdown
If the I/H converter is switched off for reasons of repair, inspection or
unit shutdown, switch off the oil supply system and relieve all pressure
reservoirs, if effective. Switch off the 24 VDC supply voltage and
remove the lines as well as piping and hose connections. Doing so, an
considerable oil quantity may leak out. Collect the oil in a suitable
container and deposit it properly. Close all holes. Now clean and pack
the I/H converter.
Disposal
In the event of disposal of the I/H converter, observe the local applicable
regulations regarding the environmental protection. The I/H converter
essentially contains steel, copper, synthetic materials, electronic
components and residual oil.