Page 15
Lift system manual
3 R e m o t e c o n t r o l
There 5 connectors for remote control options
1. Remote
1
2. Remote
2
3. AC
Trigger
4. 12VDC
Out
5. 12V
In
Remote 1 and 2 (9-pin connectors)
Remote 1 and 2 are two parallel connectors for controlling all functions of the lift system
by switching 5V to ground. Use these connectors for automation systems as Crestron,
AMX, etc. for wall switches or for the optional infra red kit PPA 360.
ATTENTION only connect voltage free switches.,
do not connect 220-230 !!
AC Trigger (3,5mm jack)
Gives 12V out to control eg. the AC power of the projector. The moment of
12V can be set via the DIP switches 1 and 2, see page 16. (moment = lift starts or stops
moving)
12 VDC Out (3,5mm jack)
Gives 12V out to control an electric projection screen. The moment of 12V
can be set via the DIP switches 3 and 4, see page 16. (moment = lift starts or stops
moving)
12V IN (3,5mm jack)
When the lift system is in Automatic mode and 12V is set on this input the
lift moves to SHOW position. 0V will move the lift system to HOME position.
12VDC Output
DIP Switches
AC Trigger
12V In
Remote 1
Remote 2
Only use a
mono
3,5 mm
plug (one
included)