Page 16
3.1 Connecting an automation/control system to Remote 1 or 2
The lift can easily be connected to automations systems as Creston, AMX, and others.
o
Use the special External control connector (included).
o
For the cable connections see Annex 1 on the next page.
o
Maximum length of cable:
o
0,35mm² (shielded) up to 30m.
o
0,50mm² (shielded) up to 150m.
Let a control system relay make contact for ½ a second and then break contact.
(Momentary 1/2 second contact mode.)
All functions can be remote controlled, however Up, Down, Stop are most used.
Warning:
To prevent unauthorised operation of specific functions we strongly recommend to
program functions as Service position, Manual mode and Emergency mode on hidden or
pass word protected pages. (when using automations systems)
3.2 DIP
switch
functions and setting for AC-trigger and 12V output
Switch off 220-230V power when setting DIP switches
Standard setting
OFF
ON
Of DIP switches
SW 1 and SW 2 for "AC trigger" output
SW 3 and SW 4 for "12V" output
DIP switch posit
Output
When
DIP switch posi
Output
When
1 2
3 4
0 V
always 12 V
0 V
ascend, home
12 V
home, descend, show, ascend
12 V
descend, show
0 V
always 12 V
0 V
home
12 V
home, descend, show, ascend
12 V
descend, show, ascend
0 V
ascend, home, descend
0 V
home, descend
12 V
show
12 V
show, ascend
0 V
ascend, home
0 V
home, descend, ascend
12 V
descend, show
12 V
show
Lift system manual