Page 18
4 P r o b l e m s o l v i n g
Clearing errors (stop LED flashing)
To delete errors from the memory, press and hold in the STOP button for 10 seconds
and then release it. If the same error occurs, refer to the troubleshooting diagram in
Annex 2.
LED blinks continuously
The no-movement switch is ON position, switch to OFF/Normal position.
LED blinks 3, 4, 5 times
These are uncommon indications, see the trouble shooting chart.
LED blinks 6 times
The cable safety sensor has been activated.
The cable sensor will be activated when the steel cables
make contact with the cable safety sensor. The lift will
stop to prevent that the cables will wind uncontrolled of
the cable drum.
Most possible causes:
o
The lift system is blocked by something.
o
The transport plates are not removed.
o
Lift system is not levelled.
o
One of the steel cables is not in the slot holes
of the descending platform and causing a
mis-balance.
Solve the problem:
1. Solve the cause, see above.
2. Press and hold the STOP button for 10 seconds to clear the error from the
memory.
3. The lift should work again now.
Lift system manual
Summary of Contents for PPL 1515