The Monitor terminals and their destinations are given in the below table:
Where the Monitor operates together with the commutator
, connection of a Door Bell button and additional
apartment handset UKP is not available. For details, refer to the commutator
operating instruction.
Note
BKM
BKM
.
See Fig. 4 - 9 for the
of the Monitor and other doorphone units.
Acceptable cross-sections of wires to connect the Monitor to the power supply unit, doorstation / control unit (Fig. 4 - 5)
are given in the doorstation / control unit operating instruction.
Acceptable cross-sections of wires to connect the Monitor to the commutator
(Fig. 6 - 9) are given in the
commutator BKM operating instruction.
examples of wiring diagrams
BKM
Terminal
LN +
LN -
GND
VI1
+E
DATA
Data exchange between Monitor and commutator BKM
Supply voltage for Monitor
Video in from doorstation camera
Ground
Intercom line between Monitor and commutator /
doorstation
Destination
Ec1
Ec2
GND
VI2
Video in from outdoor camera
Ground
Supply voltage for outdoor camera
Supply voltage for doorstation camera
HS+
HS-
Connection of additional apartment handset UKP
www.
2016-0 )
VIZIT-M441MG Operating Instruction (revision
7
vizit-group.com