background image

Figure 9 - Monitor

with Door Bell button

within multi-apartment and storey video doorphones

VIZIT-M441MG

1

4

3
2

5

6

To next commutators

BK-4MV

VO

VG

VG

-18

+18

GND
LINE

SEL
Ek

VI

Commutator

BK-4MV

1

4

3

2

5
6

1

2

3

4

Doorstation

BVD 403CPL

-

1

4

3

2

LINE
GND
+E
VO
Ec
LC

5

5

Door Bell

button

18 , А

Power Supply Unit

19w/14.4v/EU(18V/1.0A)

V  1

Commutator

BKM-441

VI1

GND

LN1-

L1

N+

GND

LN2-

+E

LN2+

VI2

Ec2

+E

GND
LN-

VO

LN+

DATA

GND

+DL

DBB

GND

+E

DC IN

1

4

2

3

To other apartments on the storey

V4

FD

LN

VG

V3

FC

LN

VG

V2

FB

LN

VG

V1

FA

LN

VG

1

4

3

2

Electromechanical strike, or

electromechanical lock

V .

max

12 /0 6А

.

+DL

-DL

LN-

GND

LN+

VI1

+E

DA

T

A

Ec1

Ec2

GND

VI2

- 44

Monitor

VIZIT M

1MG

HS

EQV.

HS+
HS-

2

4 5

1

3

6

To main entrance

doorstation /

control unit

www.

2016-0 )

VIZIT-M441MG Operating Instruction (revision

7

vizit-group.com

8 1

/1

Summary of Contents for VIZIT-M441MG

Page 1: ... view next image button Decrease value view previous image button On screen menu button AWAY mode LED indicator Image capture button Switch to additional camera button MONITOR button Power LED Screen AWAY mode button www 2016 0 VIZIT M441MG Operating Instruction revision 7 vizit group com 1 1 1 Figure Rear view 2 1 3 2 Connecting terminals to video doorphone and an outdoor camera DC IN to connect ...

Page 2: ...a Figure Installation order 3 Choose the place for the Monitor Recommended altitude is cm above the floor 150 INSTALLATION Drill three holes in the wall Drive anchors into the holes and fasten screws the fasteners are supplied with the Monitor 3 2 1 Connect wires to the Monitor terminals as shown on Figures 4 9 Match the Monitor s fixing lugs with the screws in the wall and hook the Monitor on the...

Page 3: ...orstation control unit operating instruction Acceptable cross sections of wires to connect the Monitor to the commutator Fig 6 9 are given in the commutator BKM operating instruction examples of wiring diagrams BKM Terminal LN LN GND VI1 E DATA Data exchange between Monitor and commutator BKM Supply voltage for Monitor Video in from doorstation camera Ground Intercom line between Monitor and commu...

Page 4: ...AMPLES OF WIRING DIAGRAMS Figure 4 Monitor with outdoor camera additional UKP and Door Bell button within multi apartment video doorphone VIZIT M441MG LN GND LN VI1 E DATA Ec1 Ec2 GND VI2 44 Monitor VIZIT M 1MG Door Bell button may be installed near the apartment door and connected between DATA and GND terminals GND E DC IN HS EQV HS HS 18 А Power supply unit 19w 14 4v EU 18V 1 0A V 1 VO Ec GND Ou...

Page 5: ...MV 18 18 12 12 Power Supply Unit BPD18 12 1 1 Main Monitor Individual storey doorstation activation Switching of video channels Intercom priority over additional apartment handset UKP LN GND LN VI1 E DATA Ec1 Ec2 GND VI2 44 Monitor VIZIT M 1MG HS EQV HS HS VO Ec GND Outdoor camera 12V max 0 3А 2 4 5 1 3 2 3 2 1 1 6 3 2 4 5 1 6 3 Electromechanical lock or electromechanical strike V max 12 0 6А 1N40...

Page 6: ...ND VI2 44 Monitor VIZIT M 1MG HS EQV HS HS 2 4 5 1 6 3 2 4 5 1 6 3 LN GND LN VI1 E DATA Ec1 Ec2 GND VI2 44 Monitor VIZIT M 1MG HS EQV HS HS 2 4 5 1 3 2 4 5 1 3 18 18 12 12 Power supply unit BPD18 12 1 1 1 2 1 2 2 1 Electromechanical strike or electromechanical lock V max 12 0 6А 1N4007 DL DL 1 2 3 4 5 2 1 LINE GND E VO Ec LC Doorstation BVD 405CP 1 2 4 5 1 3 18 18 12 12 Power supply unit BPD18 12 ...

Page 7: ...E GND LNM2 VOM2 LNM2 DATA_M2 HS HS C 1 Н CН2 CН3 CН4 CН5 CН6 LN GND LN VI1 E DATA Ec1 Ec2 GND VI2 44 Monitor VIZIT M 1MG HS EQV HS HS 2 4 5 1 3 LN GND LN VI1 E DATA Ec1 Ec2 GND VI2 44 Monitor VIZIT M 1MG HS EQV HS HS 2 4 5 1 3 6 6 to next commutators To next commutator 4 1 2 3 1 4 3 2 VOA FA LN G VOB FB LN G VOC FC LN G VOD FD LN G FB FA FC FB FD FC VO VG VG VI E G LINE GND Ek SEL Commutator BK 4A...

Page 8: ...nit 19w 14 4v EU 18V 1 0A V 1 Commutator BKM 441 VI1 GND LN1 L 1 N GND LN2 E LN2 VI2 Ec2 E GND LN VO LN DATA GND DL DBB GND E DC IN 1 4 2 3 To other apartments on the storey V4 FD LN VG V3 FC LN VG V2 FB LN VG V1 FA LN VG 1 4 3 2 Electromechanical strike or electromechanical lock V max 12 0 6А DL DL LN GND LN VI1 E DATA Ec1 Ec2 GND VI2 44 Monitor VIZIT M 1MG HS EQV HS HS 2 4 5 1 3 6 To main entran...

Page 9: ... Push to decrease or to increase volume Every time you push either or the test sound is ringing to present the volume level After you have chosen the volume level push the button The cursor bar jumps back to select a corresponding line in the menu Push the button and image from the selected device appears in the screen In the lower part of the screen an adjustment bar is displayed Set a preferred ...

Page 10: ...will go to stand by You can unlock the door without picking up the handset When called just press and hold until the beep The door is unlocked now After you release the Monitor will go to stand by To activate the individual storey doorstation i e start intercom and video monitoring on your initiative see Fig 5 pick up the handset Image is displayed on the screen intercom is available You can push ...

Page 11: ...tor additional apartment handset will be disengaged push the button on your Monitor when image from the camera is on the screen push the button when the Monitor is on stand by The LED indicator for AWAY mode is illuminating The Monitor captures image in 3 seconds after the call starts The LED indicator is blinking if there are new images in the Monitor s memory To quit automatic image capture mode...

Reviews: