background image

Note.

additional Monitor

Turn on the power supply unit or Commutator BKM.

Note.

Video monitoring initiated from the Monitor

Calls from the doorstation

Note

Activation of the individual doorstation

Calls from the Door Bell button or doorstation BVD

Note

Operation with an additional apartment handset UKP

Note.

intercom priority

Monitor’s

To engage the sleep mode press and hold

until the Monitor LED is off.

Special notes on operation with Commutator BKM-440

main

additional

main

intercom priority

main Monitor’s

main

If the Monitor is connected to the Commutator BKM as an

(see Fig. 7), then individual settings

for the first and second doorstation are not available, the settings will be the same for both doorstations. To perform
settings, make a call to the Monitor from either connected doorstation. Then select a ring tone, set its volume, adjust
brightness, contrast and saturation as described above.

The Monitor’s Power LED (see Fig.1) illuminates with green light.

The Power LED may not illuminate at once, after turning the power on; the delay may take up to 7 seconds. If in

7 seconds the Power LED is still dim, then the Monitor is in the sleep mode (calls are ignored, and all buttons except for

are disabled). To switch the Monitor on, push the

button.

To start video monitoring of door zone in front of the doorstation, push

, or pick up the handset. Image from the doorstation

camera is displayed on the screen
To view door zone in front of the outdoor camera, push the

button.

Where several doorstations are connected to the Monitor through the Commutator BKM, push the

button repeatedly to

view door zone in front of the connected doorstations.

When a call is made from the doorstation, the Monitor is ringing. Image from the doorstation camera is displayed on the
screen.

During intercom, push

to view image from the outdoor camera

(see Fig. 4, 5, 6), if needed. Push

again to switch back to the image from the doorstation camera.

To release the door lock, press

and hold for 1 second (until a beep). The door is unlocked now. After you release the

button, intercom is still available. Hang up the handset. The screen will shut off, and the Monitor will go to stand-by.

You can unlock the door without picking up the handset. When called, just press and hold

until the beep. The door

is unlocked now. After you release

, the Monitor will go to stand-by.

To activate the individual / storey doorstation (i.e. start intercom and video monitoring on your initiative, see Fig. 5), pick
up the handset. Image is displayed on the screen, intercom is available. You can push

to view image from the outdoor

camera, if needed. Push

again to switch back to the image from the doorstation camera.

When the Door Bell button is pushed, the Monitor is ringing and the screen switches on displaying image from the outdoor
camera (see Fig. 4, 5).
Similarly when the call button on the doorstation BVD

is pushed, the Monitor is ringing and the screen is

displaying image from the doorstation camera (see Fig.

If an additional apartment handset is connected to the Monitor, only the Monitor will be ringing, when a call is made

from the Door Bell button or doorstation BVD 403CPO

If an additional apartment handset is connected to the Monitor (see Fig. 4, 5), both the Monitor and apartment handset are
ringing when a call is made to the apartment. The Monitor’s screen is displaying image from the doorstation camera. Pick up
the UKP handset. The ringing will stop, and intercom with the doorstation will be available.

To release the door lock, push the lock release button on the UKP handset After you hang up the handset, the Monitor will
go on stand-by.

The Monitor has

over the additional apartment handset, i.e. when you pick up the

handset during intercom, the additional UKP will be disengaged, and intercom will be set between the Monitor and
doorstation.

,

The Monitor can be connected to BKM-440 either as the

or

device (see Fig. 6, 7). The

Monitor

has

over any additional device, i.e. when you pick up the

handset, the additional Monitor

or apartment handset UKP is disengaged. The additional Monitor cannot activate the individual / storey doorstation.

o  view door zone in front of the main entrance doorstation (see Fig. 6), push the      button on the

Monitor.

To switch to viewing door zone in front of the individual / storey doorstation, push the      button again.

FUNCTIONAL CHECK AND OPERATION ORDER

-403СРО

.

.

,

-403СРО

8).

-

.

.

T

.

Pick up the handset and check duplex intercom.

www.

2016-0 )

VIZIT-M441MG Operating Instruction (revision

7

vizit-group.com

10 1

/1

Summary of Contents for VIZIT-M441MG

Page 1: ... view next image button Decrease value view previous image button On screen menu button AWAY mode LED indicator Image capture button Switch to additional camera button MONITOR button Power LED Screen AWAY mode button www 2016 0 VIZIT M441MG Operating Instruction revision 7 vizit group com 1 1 1 Figure Rear view 2 1 3 2 Connecting terminals to video doorphone and an outdoor camera DC IN to connect ...

Page 2: ...a Figure Installation order 3 Choose the place for the Monitor Recommended altitude is cm above the floor 150 INSTALLATION Drill three holes in the wall Drive anchors into the holes and fasten screws the fasteners are supplied with the Monitor 3 2 1 Connect wires to the Monitor terminals as shown on Figures 4 9 Match the Monitor s fixing lugs with the screws in the wall and hook the Monitor on the...

Page 3: ...orstation control unit operating instruction Acceptable cross sections of wires to connect the Monitor to the commutator Fig 6 9 are given in the commutator BKM operating instruction examples of wiring diagrams BKM Terminal LN LN GND VI1 E DATA Data exchange between Monitor and commutator BKM Supply voltage for Monitor Video in from doorstation camera Ground Intercom line between Monitor and commu...

Page 4: ...AMPLES OF WIRING DIAGRAMS Figure 4 Monitor with outdoor camera additional UKP and Door Bell button within multi apartment video doorphone VIZIT M441MG LN GND LN VI1 E DATA Ec1 Ec2 GND VI2 44 Monitor VIZIT M 1MG Door Bell button may be installed near the apartment door and connected between DATA and GND terminals GND E DC IN HS EQV HS HS 18 А Power supply unit 19w 14 4v EU 18V 1 0A V 1 VO Ec GND Ou...

Page 5: ...MV 18 18 12 12 Power Supply Unit BPD18 12 1 1 Main Monitor Individual storey doorstation activation Switching of video channels Intercom priority over additional apartment handset UKP LN GND LN VI1 E DATA Ec1 Ec2 GND VI2 44 Monitor VIZIT M 1MG HS EQV HS HS VO Ec GND Outdoor camera 12V max 0 3А 2 4 5 1 3 2 3 2 1 1 6 3 2 4 5 1 6 3 Electromechanical lock or electromechanical strike V max 12 0 6А 1N40...

Page 6: ...ND VI2 44 Monitor VIZIT M 1MG HS EQV HS HS 2 4 5 1 6 3 2 4 5 1 6 3 LN GND LN VI1 E DATA Ec1 Ec2 GND VI2 44 Monitor VIZIT M 1MG HS EQV HS HS 2 4 5 1 3 2 4 5 1 3 18 18 12 12 Power supply unit BPD18 12 1 1 1 2 1 2 2 1 Electromechanical strike or electromechanical lock V max 12 0 6А 1N4007 DL DL 1 2 3 4 5 2 1 LINE GND E VO Ec LC Doorstation BVD 405CP 1 2 4 5 1 3 18 18 12 12 Power supply unit BPD18 12 ...

Page 7: ...E GND LNM2 VOM2 LNM2 DATA_M2 HS HS C 1 Н CН2 CН3 CН4 CН5 CН6 LN GND LN VI1 E DATA Ec1 Ec2 GND VI2 44 Monitor VIZIT M 1MG HS EQV HS HS 2 4 5 1 3 LN GND LN VI1 E DATA Ec1 Ec2 GND VI2 44 Monitor VIZIT M 1MG HS EQV HS HS 2 4 5 1 3 6 6 to next commutators To next commutator 4 1 2 3 1 4 3 2 VOA FA LN G VOB FB LN G VOC FC LN G VOD FD LN G FB FA FC FB FD FC VO VG VG VI E G LINE GND Ek SEL Commutator BK 4A...

Page 8: ...nit 19w 14 4v EU 18V 1 0A V 1 Commutator BKM 441 VI1 GND LN1 L 1 N GND LN2 E LN2 VI2 Ec2 E GND LN VO LN DATA GND DL DBB GND E DC IN 1 4 2 3 To other apartments on the storey V4 FD LN VG V3 FC LN VG V2 FB LN VG V1 FA LN VG 1 4 3 2 Electromechanical strike or electromechanical lock V max 12 0 6А DL DL LN GND LN VI1 E DATA Ec1 Ec2 GND VI2 44 Monitor VIZIT M 1MG HS EQV HS HS 2 4 5 1 3 6 To main entran...

Page 9: ... Push to decrease or to increase volume Every time you push either or the test sound is ringing to present the volume level After you have chosen the volume level push the button The cursor bar jumps back to select a corresponding line in the menu Push the button and image from the selected device appears in the screen In the lower part of the screen an adjustment bar is displayed Set a preferred ...

Page 10: ...will go to stand by You can unlock the door without picking up the handset When called just press and hold until the beep The door is unlocked now After you release the Monitor will go to stand by To activate the individual storey doorstation i e start intercom and video monitoring on your initiative see Fig 5 pick up the handset Image is displayed on the screen intercom is available You can push ...

Page 11: ...tor additional apartment handset will be disengaged push the button on your Monitor when image from the camera is on the screen push the button when the Monitor is on stand by The LED indicator for AWAY mode is illuminating The Monitor captures image in 3 seconds after the call starts The LED indicator is blinking if there are new images in the Monitor s memory To quit automatic image capture mode...

Reviews: