[VICON PROTOCOL]
If user wants to choose Vicon Protocol, the user may change the dip switch first.
(Refer to Page #36 DIP SWITCH SETTING - PROTOCOL)
Baud Rate: 4800 (Vicon default)
The operation system is almost same as Pelco D/P protocols but some special features are different way as
noted below’
<Quick Operation Key Table 2: VICON>
Number
Note
Function
1 ~ 79 +Preset
PRESET
Execute Preset 1 ~ 79
80~87 +Preset
GROUP TOUR
Execute Group Tour #1 ~ #8
88~89 +Preset
PATTERN
Execute Pattern #1 ~ #2
90 + Preset
Focus Mode Set
Focus Mode Toggle to Auto or Manual
90 + Preset Save
Pan/Tilt Lockout
PAN/TILT Lock or Unlock setting
91 + Preset Save
ZERO POSITION Search For Pan / Tilt Zero Position
92 + Preset Save
ALARM
Selectable Enable/Disable all Alarms
93 + Preset Save
BLC MODE
Selectable On/Off in BLC function
94 + Preset Save
OSD MAIN MENU To enter OSD Main Menu
95 + Preset Save
D/N MODE
Selectable Day/Night Mode (Auto/Day/Night Mode)
96 + Preset Save
SECTOR
SECTOR setting menu entrance
97 + Preset Save
DOME Reset
Initial DOME Reset - Rebooting
98 + Preset Save
AUTO PAN
AUTO PAN setting menu entrance
99 + Preset Save
Pan/Tilt Speed
Manual Pan/Tilt Max Speed setting
<Quick Operation Keys Table 2> Use these function keys if controller has these keys>
Menu
Function
Tilt Up / Down
Sub menu cursor moves up / down
Pan Left / Right
Enter to the sub menu or status change or decrement
Focus Near
Using for Enter key when user select YES or NO
Focus Far
Using for function changing keys when set coordinate
Zoom Tele
Status cursor to the right
Zoom Wide
Status cursor to the left
QUICK OPERATING KEYS
19