11
English
You should prepare a power adaptor of the sufficient capacity for supplying 24V input.
Below are the requirements:
Total consumption Power adaptor
LPC Highway
80W
7A
LPC Street
48W
5A
12.
Also pass the combo cable of the IR illuminator through a waterproof connector.
13.
Connect the day/night signal lines from the IR unit to the DI/DO connectors on the
camera's terminal block. The IP9165-HP is shown here.
DO+(5V)
DO1-
DI1+
DI0+
DI-
RS485-
RS485+
AC/DC pwr
AC/DC pwr
DO0-
The day/night mode DI connection enables the synchronization of IR light and the
automated day/night switching mechanism on the camera.
11.
Connect the Ethernet cable to the camera's RJ45 socket.
Name
Color
Gauge
Description
V+
Red
(20AWG)
Power input
12~24V DC±10%
24V AC±10% (50~60Hz), (14.5VDC current controlled)
V-
Black
(20AWG)
DI+
Green
(26AWG)
LED ON/OFF control
* Dry contact
Logic level 1(Open) = LED off
Logic level 0(Close to GND) = LED on
* Wet contact
Logic level 1: 4V~40 V = LED off
Logic level 0: 0.8V MAX = LED on
DI-
Yellow
(26AWG)
Ground
DO+
Purple
(26AWG)
Light sensor status output
1. Open = Day
2. Short = Night (20 lux for IR ON); day/night switch will have a 30 sec. delay.
DO-
Blue
(26AWG)
Ground
RS485+
Orange
(26AWG)
RS485 interface control
RS485-
Brown
(26AWG)
Cable Pinouts (IR Illuminator)
IMPORTANT: