Possible Wires
What They Control
R or V or VR
RH and RC Single power for HEAT and COOL
RH or 4
RH Power for HEAT (RH not connected to RC
jumper clip removed)
RC
RC Power for COOL (RH not connected to RC
jumper clip removed)
W
W 1st stage HEAT or 1st stage auxiliary heat
W2
W2 2nd stage HEAT or 2nd stage auxiliary heat
W3
W3 3rd stage HEATING
Y
Y COOL control or 1st stage compression for heat pump
Y2
Y2 2nd stage COOL control or 2nd stage compression
for a heat pump
G or F
G FAN control
C or X
C 24VAC power (to power thermostat)
NOTE: TRANE uses B for this connection
H
H External Humidifier
DH
DH External De-Humidifier
B
B Heat pump changeover (cool to heat, powered
in heat) For more details see B/O
O
O Heat pump changeover (heat to cool, powered
in cool) For more details see B/O
B/O
IMPORTANT: If there are both B and O wires (Trane
and American Standard heat pump products) DO NOT
CONNECT B to B terminal. Instead, connect B to C
terminal. If not a Trane or American Standard product,
tape off B.
E
n/a Emergency heat (do not connect, tape off)
L
n/a System monitor (do not connect, tape off)
T
n/a Outdoor sensor (do not connect, tape off)
Wiring Reference Table
RH
RH
RC
W
W2
A
Y
Y2
G
C
A
A
O/B
O/B
O/B
Element
Terminal
Vivint Element Installation Guide
Wiring Diagrams
Summary of Contents for SmartHome ELEMENT
Page 1: ...ELEMENT THERMOSTAT USER GUIDE...
Page 2: ......
Page 5: ...5 Getting Started...
Page 9: ...9 Wiring...
Page 16: ...16 Wiring Diagrams...
Page 24: ...24 Setup...
Page 41: ...41 Product Overview...
Page 46: ...46 Customization...
Page 59: ...140 02345 02 10 20...