Service manual
23
9.3 MSE-24CRN2
cooling mode
outdoor temperature(Dry bulb temp)
pressure
indoor
conditions
25℃
30
℃
35
℃
40
℃
45
℃
50
℃
pressure
(kg/cm2)
21
℃
D
15
℃
W
4.3
4.4
4.5
4.6
4.7
4.8
pressure
(kg/cm2)
24
℃
D
17
℃
W
4.4
4.6
4.7
4.8
5.0
5.1
pressure
(kg/cm2)
27
℃
D
19
℃
W
4.6
4.8
5.0
5.1
5.3
5.4
pressure
(kg/cm2)
32
℃
D
23
℃
W
5.1
5.3
5.4
5.6
5.7
5.9
9.4
ACP-24CH70AEB
cooling mode
outdoor temperature(Dry bulb temp)
pressure
indoor
conditions
25℃
30
℃
35
℃
40
℃
45
℃
50
℃
pressure
(kg/cm2)
21
℃
D
15
℃
W
4.3
4.4
4.5
4.6
4.7
4.8
pressure
(kg/cm2)
24
℃
D
17
℃
W
4.4
4.6
4.7
4.8
5.0
5.1
pressure
(kg/cm2)
27
℃
D
19
℃
W
4.6
4.8
5.0
5.1
5.3
5.4
pressure
(kg/cm2)
32
℃
D
23
℃
W
5.1
5.3
5.4
5.6
5.7
5.9
heating mode
outdoor conditions
indoor conditions
pressure
12
℃
D
11
℃
W
7
℃
D
6
℃
W
0
℃
D
-1
℃
W
(-4
℃
D)
(-6
℃
W)
(-7
℃
D)
(-9
℃
W)
(-15
℃
D)
(-x
℃
W)
15
℃
pressure
(kg/cm2)
22.4
20.0
18.9
17.1
16.3
/
18
℃
pressure
(kg/cm2)
23.4
21.3
20.4
18.9
17.6
/
20
℃
pressure
(kg/cm2)
23.9
22.4
21.3
19.7
18.2
/
22
℃
pressure
(kg/cm2)
24.2
23.0
22.0
20.8
19.0
/
Summary of Contents for ACP-24CH70AEB
Page 1: ...ACP 24CH70AEB RoHS Service manual ENG ...
Page 2: ......
Page 5: ......
Page 14: ...Service manual 9 5 Refrigerant cycle diagram Cooling only Heat pump mode ...
Page 18: ...Service manual 13 7 2 Wiring diagram MSE 21CRN2 MSE 24CRN2 MSE 28CRN2 ...
Page 19: ...Service manual 14 MSE 21HRN2 ACP 24CH70AEB MSE 28HRN2 ...
Page 48: ......
Page 49: ......
Page 50: ......