Service manual
34
the fan speed is kept at low speed.
The total time is 7 hours, after 7 hours the unit stops
11.11.3 Heating:
The set temperature decrease 1
℃
per hour. Two hours later, the set temperature will maintain as a
constant and the air circulation is kept at low speed (Anti-cold function takes precedence over all).
The total time is 7 hours, after 7 hours the unit stops
11.11.4 Auto:
After an hour running under economic mode, the set temp will rise 1
℃
,if it is under cooling mode; the set
temp will decrease 1
℃
,if it is under heating mode; the set temp will be changeless, if it is under fan-only
mode; the condition will be the same after the air conditioner running under economic mode after 2 hours,
and during the next time the set temp do not change. The total time is 7 hours, after 7 hours the unit stops.
11.12 Auto restart function
In case of a sudden power failure, this function automatically sets the unit to previous settings before the
power failure when power returns
11.13 Turbo mode
In cooling mode, when pressing the turbo button on the remote controller, the unit will enter turbo mode with
ultra-high speed and reach the set temperature more quickly. After running 20 minutes in turbo mode, the
indoor fan will automatically recover the preset speed.
11.14 PLASMA (optional)
Starts with indoor fan.
Note: Plasma and Anion can be use together
11.15 Anion(optional)
Starts with indoor fan.
Note: Plasma and Anion can be use together
Summary of Contents for ACP-24CH70AEB
Page 1: ...ACP 24CH70AEB RoHS Service manual ENG ...
Page 2: ......
Page 5: ......
Page 14: ...Service manual 9 5 Refrigerant cycle diagram Cooling only Heat pump mode ...
Page 18: ...Service manual 13 7 2 Wiring diagram MSE 21CRN2 MSE 24CRN2 MSE 28CRN2 ...
Page 19: ...Service manual 14 MSE 21HRN2 ACP 24CH70AEB MSE 28HRN2 ...
Page 48: ......
Page 49: ......
Page 50: ......