Accessories
50
Indoor Units
8. Accessories
Name
Shape
Quantity
Remote controller & Its
holder(The product you
have might not be
provided the following
accessories)
1. Remote controller
1
2. Remote controller holder
1
3. Mounting screw (ST2.9×10
-C-H)
2
4. Alkaline dry batteries (AM4)
2
Others
5. Owner's manual
1
6. Installation manual
1
7. Remote controller manual
1
9. The Specification of Power
Model 12000 Btu/h
18000-
24000Btu/h
30000 Btu/h
36000 Btu/h
36000 Btu/h
INDOOR
UNIT
POWER
Phase
1-phase
1-phase
1-phase
1-phase
Frequency and
Voltage
220-240V,
50Hz
220-240V,
50Hz
220-240V,
50Hz
220-240V,
50Hz
POWER
WIRING (mm
2
)
3×1.0
3×1.0
3×1.0
3×1.0
CIRCUIT
BREAKER/
Fuse (A)
15/10 15/10 15/10 15/10
OUTDOOR
UNIT
POWER
Phase
1-phase
1-phase
1-phase
1-phase
3-phase
Frequency and
Voltage
220-240V,
50Hz
220-240V,
50Hz
220-240V,
50Hz
220-240V,
50Hz
380-420V,
50Hz
POWER
WIRING (mm
2
)
3
×
2.5
3×2.5
3×2.5
3×4.0
5×2.5
CIRCUIT
BREAKER/
Fuse (A)
20/16 30/20 40/30 40/30 30/20
Indoor/Outdoor Connecting
Wiring (Weak Electric Signal)
(mm
2
)
2×0.2
2×0.2
2×0.2
2×0.2
Indoor/Outdoor Connecting
Wiring (Strong Electric Signal)
(mm
2
)
4
×
1.0
Model(Btu/h)
48000
60000
42000-60000
INDOOR UNIT
POWER
Phase
1-phase
1-phase
1-phase
Frequency and Voltage
220-240V, 50Hz
220-240V, 50Hz
220-240V, 50Hz
Power Wiring (mm
2
)
3×
1.0
3×
1.0
3×
1.0
Circuit Breaker/Fuse (A)
15/10
15/10
15/10
OUTDOOR UNIT
POWER
Phase
1-phase
1-phase
3-phase
Frequency and Voltage
220-240V, 50Hz
220-240V, 50Hz
380-415V, 50Hz
Power Wiring (mm
2
)
3
×
4.0
3
×
4.0
5
×
2.5
Circuit Breaker/Fuse (A)
40/35
50/40
30/25
Indoor/Outdoor Connecting Wiring
(Weak Electric Signal) (mm
2
)
2×0.2
2×0.2
2×0.2
Indoor/Outdoor Connecting Wiring
(Strong Electric Signal) (mm
2
)
Summary of Contents for ACP-12CC35AERI
Page 2: ......
Page 4: ......
Page 16: ...Service Space 12 Indoor Units 3 Service Space 1000mm 1000mm 1000mm 1000m m ...
Page 19: ...Air Velocity Distributions Reference Data Indoor Units 15 30 42K Cooling Heating ...
Page 20: ...Air Velocity Distributions Reference Data 16 Indoor Units 48 55Kφ φ Cooling Heating ...
Page 25: ...Field Wiring Indoor Units 21 10 Field Wiring ...
Page 33: ...Wiring Diagrams Indoor Units 29 ...
Page 34: ...Static Pressure 30 Indoor Units 5 Static Pressure ACP 24DT70AERI ACP 36DT105AERI ...
Page 35: ...Static Pressure Indoor Units 31 ACP 42DT120AERI ACP 48DT140AERI ACP 55DT160AERI ...
Page 44: ...Service Space 40 Indoor Units 3 Service Space ...
Page 46: ...Wiring Diagrams 42 Indoor Units Pre setting Instructions ...
Page 55: ...Field Wiring Indoor Units 51 10 Field Wiring ...
Page 58: ...Features 54 Indoor Units ...
Page 60: ...Service Space 56 Indoor Units 3 Service Space ...
Page 61: ...Wiring Diagrams Indoor Units 57 4 Wiring Diagrams ACP 12CC35AERI ACP 18CC50AERI ...
Page 65: ...Field Wiring Indoor Units 61 10 Field Wiring ACP 12CC35AERI ACP 18CC50AERI ...
Page 70: ...Console Type 66 Console Type 3 Service Space ...
Page 71: ...Console Type Console Type 67 4 Wiring Diagrams ACP 12CT35AERI ...
Page 76: ...Console Type 72 Console Type 10 Field Wiring ACP 12CT35AERI ...
Page 77: ...Console Type Console Type 73 ...
Page 83: ...Wiring Diagrams Outdoor Units 79 4 Wiring Diagrams ACP 12 CC CT 35AERI ACP 18 CC CF 50AERI ...
Page 84: ...Wiring Diagrams 80 Outdoor Units ACP 24 CC CF DT 70AERI ...
Page 85: ...Wiring Diagrams Outdoor Units 81 ACP 36 CC CF DT 105AERI ...
Page 86: ...Wiring Diagrams 82 Outdoor Units ACP 42 CC DT 120AERI ...
Page 87: ...Wiring Diagrams Outdoor Units 83 ACP 48 CC CF DT 140AERI ACP 55 CC CF DT 160AERI ...
Page 113: ...Refrigerant pipe installation Installation 109 ...
Page 176: ......
Page 177: ...ZZZ 9 9 FRP ...