Controller
166
Electrical Control System
controls into faceplate setting state and the LCD shows F2.Press the TEMPUP(
) to control the faceplate
up and press the TEMP DOWN( ) to control the faceplate down. Press any button to exit the faceplate
setting state, then the LCD back to the normal display.
7. ON/OFF
: For turning on or turning off the air conditioner.
8. FAN SPEED:
Fan speed will be selected in following sequence once pressing this button:
9. TIME ON:
For time ON setting. Once pressing this button, the time will increase by 0.5 hour. When the
set time exceeds 10 hours, pressing the button will increase the time by 1 hour. Adjusting the figure to 0.00
will cancel time ON setting.
10. ECO:
Select this function during the sleeping time. It can maintain the most comfortable temperature
and save energy. This function is available on COOL, HEAT or AUTO mode only .
NOTE: While the unit is running under Energy-saving mode, it would be cancelled if press MODE, FAN
SPEED or ON/OFF button.
11. TIME OFF:
For time OFF setting. Once pressing this button, the time will increase by 0.5 hour. When
the set time exceeds 10 hours, pressing the button will increase the time by 1 hour.
Adjust the figure to 0.00 will cancel time ON setting.
12. LOCK
(inner located): Push this button to lock in all the current settings, and the remote controller will
not accept any operation except that of the LOCK. Use the LOCK mode when you want to prevent settings
from being changed accidentally. Press the LOCK button again to cancel the LOCK function. A lock symbol
will appear on the remote controller display when the lock function is activated.
13.RESET
(inner located): Once the recessed RESET button is pressed, all of the current settings will be
cancelled and the controller will return to the initial settings..
AUTO
LOW
MED
HIGH
Summary of Contents for ACP-12CC35AERI
Page 2: ......
Page 4: ......
Page 16: ...Service Space 12 Indoor Units 3 Service Space 1000mm 1000mm 1000mm 1000m m ...
Page 19: ...Air Velocity Distributions Reference Data Indoor Units 15 30 42K Cooling Heating ...
Page 20: ...Air Velocity Distributions Reference Data 16 Indoor Units 48 55Kφ φ Cooling Heating ...
Page 25: ...Field Wiring Indoor Units 21 10 Field Wiring ...
Page 33: ...Wiring Diagrams Indoor Units 29 ...
Page 34: ...Static Pressure 30 Indoor Units 5 Static Pressure ACP 24DT70AERI ACP 36DT105AERI ...
Page 35: ...Static Pressure Indoor Units 31 ACP 42DT120AERI ACP 48DT140AERI ACP 55DT160AERI ...
Page 44: ...Service Space 40 Indoor Units 3 Service Space ...
Page 46: ...Wiring Diagrams 42 Indoor Units Pre setting Instructions ...
Page 55: ...Field Wiring Indoor Units 51 10 Field Wiring ...
Page 58: ...Features 54 Indoor Units ...
Page 60: ...Service Space 56 Indoor Units 3 Service Space ...
Page 61: ...Wiring Diagrams Indoor Units 57 4 Wiring Diagrams ACP 12CC35AERI ACP 18CC50AERI ...
Page 65: ...Field Wiring Indoor Units 61 10 Field Wiring ACP 12CC35AERI ACP 18CC50AERI ...
Page 70: ...Console Type 66 Console Type 3 Service Space ...
Page 71: ...Console Type Console Type 67 4 Wiring Diagrams ACP 12CT35AERI ...
Page 76: ...Console Type 72 Console Type 10 Field Wiring ACP 12CT35AERI ...
Page 77: ...Console Type Console Type 73 ...
Page 83: ...Wiring Diagrams Outdoor Units 79 4 Wiring Diagrams ACP 12 CC CT 35AERI ACP 18 CC CF 50AERI ...
Page 84: ...Wiring Diagrams 80 Outdoor Units ACP 24 CC CF DT 70AERI ...
Page 85: ...Wiring Diagrams Outdoor Units 81 ACP 36 CC CF DT 105AERI ...
Page 86: ...Wiring Diagrams 82 Outdoor Units ACP 42 CC DT 120AERI ...
Page 87: ...Wiring Diagrams Outdoor Units 83 ACP 48 CC CF DT 140AERI ACP 55 CC CF DT 160AERI ...
Page 113: ...Refrigerant pipe installation Installation 109 ...
Page 176: ......
Page 177: ...ZZZ 9 9 FRP ...