HEAT MODE
If the air conditioner is off and then turned on while set at COOL ,HEAT or DRY mode, it will
take approximately 3 minutes for the compressor to start.
The ST at heat mode is adjustable within16
℃
-31
℃
.
When RT ST, the compressor stops; when RT<ST-1 , the compressor starts.
≥
℃
Once turning on the unit while set at heat mode, if all the conditions meet with the
requirement of compressor operation, the four-way valve gets charged and 8 seconds later,
the compressor and outdoor fan start running.
Heat overload protection:
For R22 series, when
when PT
≥
63
℃
, the compressor stops.
PT
≥
50
℃
, the outdoor fan stops; when PT
≤
47
℃
, the outdoor fan starts;
Deice control:
Conditions for activating deice:
a. The working hours of compressor accumulates to be 40 minutes.
b. When OT
≤
-4
℃
for 1 minute.
Conditions for terminating deice:
a. When OT
≥
15
℃
for 1 minute.
b. Over 10 minutes of deicing operation.
CONTROL SPECIFICATION
Electric-heat control:
Conditions for initiating electric-heat function:
a. RT
≤
23
℃
; b. RT+3
℃≤
ST; c. The indoor fan runs;
d. Turn on the electric-heat key; e. PT<50
℃
Conditions for terminating electric-heat function:
a. PT 50 ; b. RT 26 ; c. The indoor fan stops running;
d. Turn off the electric-heat key; e. Mode change.
≥
℃
≥
℃
Conditions for terminating electric-heat function:
a. PT 50 ; b. RT 26 ; c. The indoor fan stops running;
d. Turn off the electric-heat key; e. Mode change.
≥
℃
≥
℃
OT
15
℃
-4
℃
COMP
ON
OFF
OFAN
ON
OFF
ON
OFF
4-way
valve
TIME
30S
15S
30S
15S
10 minutes at most
18
Strong-wing prevention :
A.PT<27,the indoor fan stops running, the swing louver cannot be controlled by the remote
controller.
B.34>PT
≥
27,the indoor fan runs at low speed, the sweep louver erects.
C.PT
≥
34,the indoor fan and the swing louver can be controlled normally.
Summary of Contents for ACP-07CH21ZNLO
Page 1: ...ACP 07CH21ZNLO ACP 09CH25ZNLO ACP 12CH35ZNLO Service manual ENG RoHS ...
Page 2: ......
Page 30: ...ACP 07CH21ZNLO O ACP 09CH25ZNLO O Exploded Views and Parts List 31 ...
Page 31: ...ACP 07CH21ZNLO O ACP 09CH25ZNLO O ...
Page 32: ...ACP 12CH35ZNLO O ...
Page 37: ......
Page 38: ......
Page 39: ......