Wiring
2
Open the front grille;
Remove the screw from electrical box cover, pull the
electrical box cover away from the unit and set aside.
Remove the screw from fastener, pull the fastener
away from the unit and set aside.
Connect the cable.
Replace the fastener and electrical box cover.
Indoor unit terminal
Screw
Connecting cable
Diagram
INSTALLATION
The drain hose must be arranged beneath the copper pipe.
The drain hose must not be hunched or twisted.
While wrapping up the drain hose, do not pull it.
The drain hose through the room must be wrapped up by the
thermal insulation materials.
The copper pipe and the drain hose must be wrapped up by felt
strip. Adiabatic pad should be used at where the pipe contacts
the wall.
NOTE:
1
2
3
ROUTE OF PIPE
If pipe comes out of the right side of the indoor unit, cut part
“
1
”
of the unit;
If pipe comes out of the lower-right side of the indoor unit, cut
part
“
2
”
of the unit;
If pipe comes out of the left side of the indoor unit, cut part
“
3
”
of the unit.
Installation of the drain hose
3
Drain hose
gas pipe
Liquid pipe
felt
Adiabatic
underlay
drain hose
If pipe comes out of the left side of the indoor unit, the drain hose
must be refitted, otherwise water leakage may occur.
Refit methods: Interchange the position of drain hose and drain
rubber plug.
Clearance is not allowed after refit, it would lead to water leakage.
Drain rubber
plug
REFIT OF DRAIN HOSE
5
NOTE:
The appliance shall be installed in accordance with national wiring regulations.
The appliance must not be installed in the laundry.
The appliance must be installed 2.3m above the floor.
The appliance must be positioned so that the plug is accessible.
For some models whose cooling capacity are above 4600W (17000BTU/h),
an all-pole disconnection device which has at least 3mm separation distance in
all pole and a residual current device(RCD)with the rating of above 10mA shall
be incorporated in the fixed wiring according to the national rule.
Summary of Contents for ACP-07CH21ZNLO
Page 1: ...ACP 07CH21ZNLO ACP 09CH25ZNLO ACP 12CH35ZNLO Service manual ENG RoHS ...
Page 2: ......
Page 30: ...ACP 07CH21ZNLO O ACP 09CH25ZNLO O Exploded Views and Parts List 31 ...
Page 31: ...ACP 07CH21ZNLO O ACP 09CH25ZNLO O ...
Page 32: ...ACP 12CH35ZNLO O ...
Page 37: ......
Page 38: ......
Page 39: ......