INSTALLATION
8
If the interconnection cord for power supply has to be replaced, please see the
following table for reference.
Notice:
If the signal wire has to be bought separately, choose electric wire above 0.75mm.
SERIES
MODEL
IMPEDANCE
6800W (24000BTU/h)
5100W (18000BTU/h)
3200W (1000BTU/h)
3500W (12000BTU/h)
R22
series
≤
0.042
Ω
≤
0.160
Ω
≤
0.132
Ω
≤
0.121
Ω
2500W (9000BTU/h)
≤
0.457
Ω
MODEL SPECS (Interconnection cord)
≤
2700W(10000BTU/h)
≥
1.0mm
3000W(11000BTU/h) -4000W(15000BTU/h)
4500W(18000BTU/h) -8000W(28000BTU/h)
≥
2.5mm
1.5mm
≥
2
2
2
2
WARNING:
Special cable must be used to connect indoor unit and outdoor unit. It should be ensured
that the terminals are not influenced by external force. Poor connection may cause fire.
The electric box cover must be mounted and secured in position, otherwise fire or electrical
shock may occur because of dust or moisture.
The connecting cables must be clipped together.
Please take the electric circuit diagram attached to the indoor/outdoor units as major
reference while installing.
The power wire and signal wire between the indoor/outdoor units must be connected
one by one as per corresponding number on the wiring terminal board.
All the models shall be connected with the mains which has system impedance limitations.
While installing the unit, please see the following table for impedance information or
consult with the supply authority.
The temperature of refrigerant circuit will be high, please keep the interconnection cable away
from the copper tube.
Summary of Contents for ACP-07CH21ZNLO
Page 1: ...ACP 07CH21ZNLO ACP 09CH25ZNLO ACP 12CH35ZNLO Service manual ENG RoHS ...
Page 2: ......
Page 30: ...ACP 07CH21ZNLO O ACP 09CH25ZNLO O Exploded Views and Parts List 31 ...
Page 31: ...ACP 07CH21ZNLO O ACP 09CH25ZNLO O ...
Page 32: ...ACP 12CH35ZNLO O ...
Page 37: ......
Page 38: ......
Page 39: ......