Vitrolux E / F
Technical Data
Stand 5/12
Page 53 of 58
7.1 General Data
System
Dimensions
(WxDxH) mm
Table
(WxD)mm
Engraveable
area (WxDxH)
mm
Engraveable
area with doors
Weight
kg
Vitrolux E-S 1420x1150x1870 700x600
700x600x95
500x400x95
Ca. 400
Vitrolux E-M 1420x1450x1870 700x900
700x900x95
500x700x95
Ca. 440
Vitrolux E-L
1920x1450x1870 1250x1000
1200x900x95
1000x700x95
Ca. 550
Vitrolux E-X 1920x1950x1870 1250x1500
1200x1400x95
1000x1195x95
Ca. 620
Vitrolux F-S 2216x2430x1600 1750x2250
1500x1700x95
Ca. 540
Vitrolux F-M 3216x2430x1600 2750x2250
2500x1700x95
Ca. 610
Vitrolux F-L
2716x3750x1600 2250x3250
1700x3000x95
Ca. 680
7.2 Environmental conditions
Production environment
Vibration-free, dust-free room, air without aerosols
Air temperature
15 to 32°C (with even warming)
Min. floor load-bearing capacity
400-500 kg/m² depending on type of machine (see 7.1)
Spatial requirements
1 m (clearance) System cabinet
7.3 Electrical installations
Power supply (single phase)
:
110 - 230 V AC, 50 – 60 Hz
Power consumption:
max. 700W
Fuse:
2 x 6,3 A / 250V träge
7.4 Laser
Laser type:
Diode pumped solid state Laser
Wave length, laser head:
532 nm
Average laser power:
Max. 2 W
Laser repeat pulse:
max. 10 kHz
Average usable frequency:
4 kHz
Puls length:
< 10 ns
max. pulse energy:
0,5 mJ
Wavelength scanner:
532 nm
Wavelength:
790 to 820 nm
Laser diode modul max.:
40W
Wavelength pilot laser ca.:
650 nm
Laser class
- normal operation with doors:
Laser class 1
- Maint inching:
Laser class 4
Scan field in flat glass:
70mmØ
Working distance:
132,2 mm