3.8 PC Console
In the PC Console a complete PC is installed in addition to the already mentioned special
keys and indicators.
Through the Windows interface the pre-installed software "VitroMark" can be called, which
takes over the complete control of the laser processing.
3.9 Function setting safety contacts
(Laser class 1 with doors only)
All doors on the laser class 1 systems are fitted with safety devices.
These safety devices can be operated in 2 ways:
Door is locked during the laser process and cannot be opened (the default). The "cover"
button must be pressed to open the doors always. This effectively prevents errors by
accidental opening of the doors during the process.
The door can be opened at any time without having to press the "cover" button, but the
opening of the door is supervised and the laser immediately switched off if a door is opened.
This can be useful on large machines with only one operator because he does not have to
press the "Cover" button with one hand and open the door with the other hand at the same
time
However broken laser operations can not be continued by accidental opening of the doors.
The process must be restarted.
The operation of the door contacts can be switched with the special key supplied.