background image

Portavant 80 automatic

 

 

 

29 

Revision 12/2017 

Display lights up when 
pressing "Menu" button, all 
settings are displayed, but 
"+" and "-" buttons do not 
work 

User menu has been 
disabled by installer, e.g. in 
hotels, to prevent tampering 
by guests or to increase 
safety (reduced motion 
speed, exclusion of 
automatic mode) 

To enable the user menu, 
contact the installation 
contractor; it may be 
necessary to coordinate a 
new safety concept with the 
operator (see safety 
analysis) 

Door responds, display does 
not work 

– even when 

pressing a button 

Data cable (ribbon cable) 
between drive unit and 
control panel is interrupted 

Check connectors on both 
data cable ends for secure 
fit; check cable for damage 
(note: the connectors may 
be plugged in in either 
orientation) 

Display/control panel is 
defective 

Replace display/control 
panel 

Control system/output of 
drive unit is defective 

Replace drive unit 

Door has stopped out of end 
position, display shows 
"Push to continue". If the 
display is off, press "Menu" 
and check for display 
message 

Collision with obstacle in 
both directions or double 
contact during opening 

– 

door has been disabled  

Remove obstacles, if 
required, then push-start 
door in either direction 

Door keeps stopping at the 
same position out of its end 
position, display does not 
show any message 

Teach-in cycle was 
interfered 

– door assumes 

an incorrect end position 

Repeat teach-in cycle (using 
the Reset button, see 
operating instructions) 

Door stops at different 
positions without having 
collided with an obstacle and 
then reverses 

Door assumes to have 
detected a collision 

Check track profile for 
obstacles; check door for 
smooth operation 

Door moves beyond its end 
positions or end positions 
move out of their set 
positions 

Caution! End stops are loose  Adjust end stops according 

to the instructions and 
tighten them 

Audible vibrations during 
door motion 

Track profile is tensioned 

Check underlying structure 
and rectify 

 

Belt tension is insufficient 

Increase belt tension 

Loud but regular noise 
during door motion 

Unsuitable underlying 
structure (e.g. resonance in 
hollow wall) 

Change the underlying 
structure (e.g. by bracing, 
wooden reinforcement, 
cavity filling, sound-
absorbing film or foam) 

Track rollers are damaged  

Check track rollers for 
damage and replace roller 
assembly, if required 

Loud but erratic noise during 
door motion 

Objects in track profile 

Remove objects, including 
chips from drilling and dust, 
etc., clean and check track 
rollers 

Track profile is damaged 

Check track profile for 
damage 

 
 
 

Summary of Contents for Portavant 80 automatic

Page 1: ...Manual EN Gebr Willach GmbH Stein 2 53809 Ruppichteroth Germany...

Page 2: ...9 4 Technical data 10 5 System overview 11 6 Installation and commissioning by the installer 12 7 Safety analysis by the installer according to DIN 18650 EN 16005 13 7 1 Performing the safety analysi...

Page 3: ...re to perform all steps required for installation and commissioning and observe all information instructions and precautions provided before operating the drive system Observe the operating instructio...

Page 4: ...e not allowed This excludes in particular the use of Portavant 80 automatic for shower doors or doors in saunas steam baths or swimming pools The system may only be used with single sash doors weighin...

Page 5: ...of the door kg v velocity of the door m s DANGER Risk of crushing shearing impact To avoid potential danger the installer must perform a safety analysis according to DIN 18650 EN 16005 see section 7 2...

Page 6: ...ble hazard to particularly vulnerable persons then the operating mode of the door can be changed and set in such a way that the mode e g semi automatic or manual cannot be manipulated without major in...

Page 7: ...fuse switch or circuit breaker After removing the aluminium cover profile pull the mains connector at the housing of the drive unit to prevent unintended reconnection to mains power by third parties...

Page 8: ...motion is imminent Check the settings and functionality of the Portavant 80 automatic system after installation The installation described in this manual is an example The situation on site the build...

Page 9: ...de This mode allows the door to be moved manually like a sliding door without power assistance In this mode the motor drive is disabled All signal senders push buttons motion detectors etc are disable...

Page 10: ...dedicated terminals provided at the drive unit 3 4 Collision with obstacles If a door collides with an obstacle in its travel path it stops immediately to return to its opposite end position Depending...

Page 11: ...No splash water Protection class IP 20 Permissible door dimensions Door weights for single sash operation 20 to 80 kg 200 800 N Door weights for double sash operation 20 to 60 kg 200 600 N per sash Ca...

Page 12: ...button 14 Two line display 15 button 16 Reset button 17 LED of radio receiver if applicable 18 Position of optional radio receiver 1 Track profile and cover profile 2 Drive and control unit 3 Supply...

Page 13: ...ify the production date of the drive unit see CE sticker on drive unit The installer must perform a safety analysis in accordance with section 7 before installing the Portavant 80 automatic system The...

Page 14: ...0 EN 16005 or Directive on Machinery 2006 42 EC must create a EC declaration of conformity and attach a CE mark at the doorset In general avoiding points of danger always takes priority Door data Buil...

Page 15: ...____________________________________________ Street ________________________________________________ Post code City ________________________________________________ Date ___________________________ Si...

Page 16: ...or closing sash is avoided else suitable safety measures must be in place e g by maintaining safety clearances or by providing protection wings and by limiting door operating forces by low kinetic en...

Page 17: ...r the body crushing s 100 then y 500 c Danger for the body crushing s 500 then y 0 d Finger protection shearing s 8 then t 0 s 8 then t 25 e Finger protection drawing in Fingers s 8 or 25 s 30 f Clear...

Page 18: ...edes the door weight This is a prerequisite to ensure that the maximum door speeds calculated from the door weight comply with the low kinetic energy mode according to DIN 18650 EN 16005 Incorrect ent...

Page 19: ...set must be increased by reducing the opening speed as long as the opening speed still allows comfortable passage of the door AND OR reducing the closing speed AND OR selecting semi automatic mode AND...

Page 20: ...assification have already been printed onto the label on the drive unit by the manufacturer Willach Classification DIN 18650 I 2 I 1 I 2 I 0 I 1 3 I 0 I __ __ __ I 4 I 1st digit Drive type 2 Sliding d...

Page 21: ..._____________________________________________________________________ We hereby declare that the complete sliding doorset driven by the automatic drive system for sliding doors of type Portavant 80 au...

Page 22: ...speed Press or to select a percent value from the list 100 corresponds to the maximum permissible opening speed in low kinetic energy mode according to DIN 18650 EN 16005 The opening speed can be redu...

Page 23: ...a teach in cycle Teach in mode Push to continue Push the door into either direction Ensure that the travel path of the door is free of any obstacles as the subsequent teach in cycle will determine th...

Page 24: ...ut of reach of children Radio or wired wall button optional function The wall mounted radio or wired push button has the same function and is operated in the same way as the radio remote control DANGE...

Page 25: ...8 1 Settings via the user menu Party mode Power failure In case of power failure the door can be operated like a manual sliding door DANGER Risk of crushing shearing impact In case of power failure th...

Page 26: ...t see section 7 1 for evaluation of the door weight Execution and documentation of the safety analysis in accordance with section 7 1 Creation of a declaration of conformity in accordance with section...

Page 27: ...mber designation Serial number of drive Date Inspection Result Measure Name Signature Commission ing Acc to checklist Com missioning Input door weight __________ kg Low kinetic energy movement ensured...

Page 28: ...checklist Acc to checklist Acc to checklist Acc to checklist Acc to checklist Acc to checklist Acc to checklist Acc to checklist Acc to checklist Acc to checklist Acc to checklist Acc to checklist Ac...

Page 29: ...display lights up when pressing Menu but does not show any message Door is in manual mode Check operating mode in user menu and change it if required see operating instructions Drive is defective Repl...

Page 30: ...sh start door in either direction Door keeps stopping at the same position out of its end position display does not show any message Teach in cycle was interfered door assumes an incorrect end positio...

Page 31: ...49 0 2295 9208 422 or 427 vitris willach com Monday through Friday 7 30 a m to 4 30 p m In case of malfunctions or defects please contact the service support line at 49 0 2295 9208 500 Monday through...

Page 32: ...Portavant 80 automatic 31 Revision 12 2017 12 Declaration of Incorporation Conformity and type examination by T V 12 1 EC Declaration of Incorporation...

Page 33: ...Portavant 80 automatic 32 Revision 12 2017 12 2 EC Declaration of Conformity...

Page 34: ...Portavant 80 automatic 33 Revision 12 2017 12 3 Type examination by T V...

Page 35: ...Portavant 80 automatic 34 Revision 12 2017...

Page 36: ...Portavant 80 automatic 35 Revision 12 2017 13 Appendix 13 1 Parts overview and designations Parts overview...

Page 37: ...oothed belt 6 Roller assembly 7 Clamping pieces 8 Cover profile 9 Motion stop 10 Radio receiver 11 Drive and control unit 12 Control panel 13 Door sash 14 Floor guide sliders 15 Floor guide 16 Remote...

Page 38: ...Imprint 37 Revision 12 2017 Imprint Gebr Willach GmbH Stein 2 53809 Ruppichteroth Germany Phone 49 0 2295 9208 421 or 427 Fax 49 0 2295 9208 429 Website www willach com E mail vitris willach com...