Transcendent VT-TR5HA DVR Series
47
Select the camera and enable PTZ and then set the protocol, baud rate and address of the dome
according to the settings of the dome.
Protocol
: The default communication protocol of the DVR is COC. Range from: PELCOP,
PELCOD, LILIN, MINKING, NEON, STAR, VIDO, DSCP, VISCA, COC, etc.
Address
: The address of the PTZ device.
Baud Rate
: Baud rate of the PTZ device. Range from: 110, 300, 600, 1200, 2400, 4800, 9600,
19200, 34800, 57600, 115200, 230400, 460800, 921600.
Transcendent VT-TR5HA DVR Series
48
7
Record & Disk Management
7.1 Record Configuration
7.1.1 Mode Configuration
Please format the HDDs before recording (refer to 7.5 Disk Management for details). Click
Start
à
Settings
à
Record
à
Mode Settings to go to the mode settings interface. You can set the
record time under “Manual Record Settings” and then click “Apply” button to save the settings.
There are two record modes: auto mode and manual mode.
Ø
Auto Mode
Motion Record
: Motion alarm record will be enabled when motion alarm happens.
Sensor Record
:
Sensor alarm record will be enabled when sensor alarm happens.
Motion Sensor Record
:
Motion/sensor alarm record will be enabled when
motion/sensor alarm happens.
Always (24
ⅹ
7) Motion Record
:
Normal record is enabled all the time; motion alarm
record will be started when motion alarm happens.
Always (24
ⅹ
7) Sensor Record
: Normal record is enabled all the time; sensor alarm
record will be started when sensor alarm happens.
Always (24
ⅹ
7) Motion Sensor Record
:
Normal record is enabled all the time;
motion/sensor alarm record will be enabled when motion/sensor alarm happens.
You can add more auto modes on intelligence record. Click “Advanced” button to pop up a
window as shown below. Check the modes in the window and then click “Add” button to show
the modes in the record mode list (in the window, the checked modes can be showed in the
record mode list while the unchecked modes cannot; you can add 3 modes at most).