![Vitek VT-TNR1646PF User Manual Download Page 159](http://html.mh-extra.com/html/vitek/vt-tnr1646pf/vt-tnr1646pf_user-manual_1035427159.webp)
VITEK Industrial Video Products – Transcendent Series NVRs
149
Enter the sender’s name, e-mail address, SMTP server and SMTP port (you can click “Default”
to reset the SMTP port to the default value) and then enable or disable the SSL and attaching
image. Select the username (the username list will be updated automatically according to the
email address you enter) and enter the password of the sender and then click “Apply” to save the
settings (you don’t have to enter the username and password if “Anonymous Login” is enabled).
Click “Test” to pop up a window. Enter the e-mail address of the recipient in the window and
then click “OK”. The e-mail address of the sender will send an e-mail to the recipient. If the e-
mail is sent successfully, it indicates that the e-mail address of the sender is configured correctly.
Click “Edit Recipient” to go to the following interface.
Click “Add” and then enter the recipient’s e-mail address and select the schedule (if a schedule
is selected, the system will send the alarm email and the recipient will receive it only in the
selected schedule time) in the popup window. Click “Add” in the window to add the recipient.
You can also change the recipient’s receiving schedule by clicking
in the “Schedule”
column. Click
to delete the recipient in the list. Click “Apply” to save the settings. Click
“Edit Sender” to go to the e-mail configuration interface of the sender.
VITEK Industrial Video Products – Transcendent Series NVRs
150
13.1.6 UPnP Configuration
By UPnP you can access the NVR through web client which is in WAN via router without port
mapping.
①
Click Start
à
Settings
à
Network
à
UPnP to go to the following interface.
②
Make sure the router supports UPnP function and the UPnP is enabled in the router.
③
Set the NVR’s IP address, subnet mask and gateway and so on corresponding to the router.
④
Check “Enable” in the interface as shown below and then click “Apply”.
Click the “Refresh” button to refresh the UPnP status. If the UPnP status is “Invalid UPnP” after
refreshing it a few times, the port number may be wrong. Please change the mapping type to
“Manual” and then click
to modify the port until the UPnP status turns to “Valid UPnP”.
Refer to the following picture. You can view the external IP address of the NVR. Enter the
external IP address plus port in the address bar to access the NVR such as http://123.45.678.91:81.
13.1.7 802.1X
If it is enabled, the NVR data can be protected. When the NVR is connected to the network
protected by the IEEE 802.1X, user authentication is needed.
To use this function, the NVR should be connected to a switch supporting 802.1x protocol. The
switch can be considered as an authentication system to identify the device in a local network. If
the NVR connected to the network interface of the switch has passed the authentication of the
switch, it can be accessed via the local network.
Summary of Contents for VT-TNR1646PF
Page 185: ...NOTES ...