12
Salt Setting
Brine & Rinse (time - min:sec)
Brine Refill (time - min:sec)
Low salt setting
37:00
1:30
Medium Salt Setting
50:00
2:00
High Salt Setting
55:00
2:30
The time settings for Brine & Rinse and Brine Refill are in the tables below at low, medium and high salt setting.
Time Settings For Brine Refill And Brine & Rinse At Low Salt Setting (table D):
If changing the salt setting to low or high salt setting, the first step is to change the capacity (Amount of Soft Water Available) by
following the procedure in Section 4 “Set Capacity”. Use the tables A or C on pg 11.
To change the salt setting from the default medium salt setting to low or high salt setting the times for Brine & Rinse and Brine
Refill have to be changed. Follow the steps below.
Step 1.
If starting at In-Service menu press Menu/Return key
to switch to the main menu. If continuing in the main menu
scroll down to “Advance Settings” using the arrow keys.
Step 2.
Press the Menu/Confirm Key
to enter the “Advance Settings” sub menu.
Step 3.
Scroll down to “Brine and Rinse” in the sub menu set up using the down arrow key
.
Step 4.
Press the Menu/Confirm Key
and the minutes in the “Brine and Rinse” will start flashing. Use the appropriate values
in Table D to adjust the times if you prefer low salt setting or high salt setting.
Step 5.
Use the down or up arrow keys
to scroll to the correct minutes.
Step 6.
Press the Menu/Confirm Key
and the seconds will start flashing. Use the appropriate values in Table D to adjust the
times for your preference of low or high salt setting. Use the down or up arrow keys
to adjust to the correct
minute setting.
Step 7.
Press the Menu/Confirm Key
and menu will return to the main menu “Brine and Rinse”.
Step 8.
Scroll down to “Brine Refill”.
Step 9.
Press the Menu/Confirm Key
and the minutes in the “Brine Refill” will start flashing. Use Table D to select the time
for your preference of low or high salt setting.
Step 10. Use the down or up arrow keys
to scroll to the correct minutes.
Step 11. Press the Menu/Confirm Key
and the seconds will start flashing. Use table D to select the seconds. Use the down
and up arrow keys
to adjust to the correct seconds setting.
Step 12. Press the Menu/Confirm Key
and menu will return to set-up menu “Brine Refill”.
Step 13. Press Manual/Return Key twice
to proceed back to the In Service Display screen if no other parameters are
going to be changed.
6.
Calendar Day Override:
The calendar day override has been set to 14 days. This means if the water softener water capacity is not used up in 14 days it will
regenerate automatically to help prevent resin fouling.
7.
Manual Regeneration:
1. Sometimes there is a need to regenerate the system sooner than when the system call for it, usually referred to as manual
regeneration. There may be a period of heavy water usage because of guests or a heavy laundry day. To initiate a manual
regeneration immediately, press the Manual/Return key
. The control valve will cycle through the following regeneration cycles:
Backwash • Brine Draw & Slow Rinse • Fast Rinse • Fill Brine Tank • Back to In Service
Note: Regeneration cycle will take approximately 54 minutes to complete.
2. When the regeneration cycles are completed the valve will return to the in-service mode.
3. The only way to cancel a manual regeneration is to cycle fast through the steps by pressing the
Manual/Return Key
repeatedly after every cycle until the valve returns to service mode.
8.
Power Loss:
If the power outage exceeds 3 days (72 hours) the clock will need to be reset. When the power is turned on the clock figure
will flicker continuously. This reminds owner to reset the time. All other parameters will not need to be reset.
9.
Hard Water Notice:
During softener regeneration cycle, only hard water will be available in the facility.
10. Error Message:
If the errors E1, E2, E3 or E4 show on the display screen contact the dealer for assistance.