2 9
2 8
3. Move lever fuel control by your hand in the direction of the arrow «RUN»
(see fig. 8).
4. Put the ignition key into the ignition and turn to position «START» (see
fig. 9). Hold the key in this position until the engine starts, then, release the
key. To prevent failure of the generator, do not hold the key to the position
«START» more than 15 seconds.
ELECTRIC STARTER'S LAUNCH
1. Put battery on the regular place. Observing polarity, connect the power
cables to the battery (black "Grounding" to "-", red «Starter» to "+").
2. Open the fuel cock. Turn the fuel cock lever «FUEL COCK» in position
«ON» («OPEN») (see fig. 6 - ERS 4.6 d model, fig. 7 - ERS 4.6dt model).
CAUTION
!
Be sure that the AC circuit breaker is disconnected! It is
forbidden to launch the generator's engine if the electricity
consumers are connected to the device. The connected load
makes it difficult to launch the engine and may damage it.
NOTE
!
ERS 4.6d engine model can be launched by a manual and
electric starter. ERS 4.6dt engine model is not equipped with a
manual starter and is launched only by an electric starter.
figure
6
figure
7
1
2
1. Fuel control lever.
2. Engine stop lever.
figure
8
figure
9
WARNING
!
If the engine does not start within 15 seconds, release the
ignition key, wait for 15-20 seconds (this allows the battery to
recover) and try again.