VitalConnect Vista Solution VistaPoint 2.0 Manual Download Page 2

 

 

IFU-08, Rev D  |  Date: November 2019 

Page 2 of 39 

 

Table of Contents 

Chapter 1

 

About This Document ........................................................................................................... 3

 

Disclaimer .................................................................................................................................................. 3

 

Related Documents ................................................................................................................................... 3

 

Indications for Use ..................................................................................................................................... 3

 

About VitalConnect, Inc. ............................................................................................................................ 4

 

Chapter 2

 

Preparing for Monitoring ...................................................................................................... 5

 

Chapter 3

 

Pairing VitalPatch to VistaPoint ........................................................................................... 7

 

Chapter 4

 

Using the VistaPoint Dashboard ........................................................................................ 10

 

Verify Correct Display of Vital Signs ........................................................................................................ 10

 

Using the VistaPoint Menu ...................................................................................................................... 11

 

Using the VitalPatch Menu ...................................................................................................................... 11

 

Dashboard Features ................................................................................................................................ 12

 

Checking VistaTablet and VitalPatch Battery Levels .............................................................................. 13

 

Chapter 5

 

When Monitoring is Complete ............................................................................................ 14

 

Chapter 6

 

Troubleshooting .................................................................................................................. 15

 

Message “VitalPatch Off Body” ............................................................................................................... 15

 

Message “VitalPatch Not Connected” ..................................................................................................... 16

 

Message “Patch Expires” or “Replace VitalPatch” .................................................................................. 17

 

Bluetooth Connection Issues ................................................................................................................... 17

 

Dashboard Stops Updating ..................................................................................................................... 17

 

Cannot Power-On VistaTablet ................................................................................................................. 18

 

Chapter 7

 

Using the Nonin Model 3150 Pulse Oximeter ................................................................... 19

 

Chapter 8

 

Using the Nonin Model 3230 Pulse Oximeter ................................................................... 24

 

Chapter 9

 

Using the A&D Medical UA-651 Blood Pressure Monitor ............................................... 29

 

Chapter 10

 

Using the A&D Medical UC-352 Scale ............................................................................... 34

 

General symbols ...................................................................................................................................... 39

 

Legal Information ..................................................................................................................................... 39

 

Contact Information ................................................................................................................................. 39

 

Summary of Contents for Vista Solution VistaPoint 2.0

Page 1: ...IFU 08 Rev D Date November 2019 Page 1 of 39 VitalConnect Vista Solution VistaPoint 2 0...

Page 2: ...12 Checking VistaTablet and VitalPatch Battery Levels 13 Chapter 5 When Monitoring is Complete 14 Chapter 6 Troubleshooting 15 Message VitalPatch Off Body 15 Message VitalPatch Not Connected 16 Messa...

Page 3: ...51 Scale A D Medical Model UC 352 Disclaimer This document is not intended to replace the Instructions for Use IFU documents for the VitalPatch biosensor nor the approved third party devices Always re...

Page 4: ...l minutes after the biosensor has been applied to the patient to register accurate skin temperature values About VitalConnect Inc VitalConnect is a leader in wearable biosensor technology for wireless...

Page 5: ...the VistaTablet plugged into the charger You can use the VistaTablet device while it is charging Step 2 Turn On VistaTablet The VistaTablet should always be ON when you are wearing a VitalPatch biose...

Page 6: ...tch Refer to the VitalPatch Instructions for Use IFU 02 or IFU 06 Step 5 Apply VitalPatch Biosensor a Power on and apply the VitalPatch biosensor according to the Instructions for Use for your VitalPa...

Page 7: ...list of VitalPatch Biosensors that are within Bluetooth range of the relay Find the Bluetooth ID of the biosensor that you have powered on in the list and select it If the Bluetooth ID does not appea...

Page 8: ...at can be elevated position the bed angle at 30 Note that the Elevated posture will only be selectable as an option if the VitalPatch biosensor has firmware 3 2 0 0 or higher If the Elevated option is...

Page 9: ...he Body Temperature display will not show a value select the Calibrate button when calibration can be performed The VistaPoint dashboard will be displayed after performing or skipping the temperature...

Page 10: ...Display of Vital Signs After pairing and calibrating verify that data is flowing from the connected VitalPatch biosensor to the VistaPoint application Streaming data will be displayed on the dashboar...

Page 11: ...tion of the VistaPoint application From this menu you can Disconnect VitalPatch Select this option if a biosensor needs to be disconnected but other third party devices are to remain connected or you...

Page 12: ...le will display a fall status To clear acknowledge the event select the Acknowledge button in the Fall Detection tile Live ECG mV s scale 10mm mV at 25mm s The collection and display of ECG data is a...

Page 13: ...e VistaTablet for an hour before turning it on again Use only the provided cable and charger to charge the VistaTablet Keep the VistaTablet plugged into the charger You can use the VistaTablet device...

Page 14: ...rge Patient Choose this option if you will NOT be applying a new VitalPatch biosensor All devices will be disconnected Step 2 Remove VitalPatch Biosensor a To remove the VitalPatch refer to the VitalP...

Page 15: ...message will be displayed see figure to the right Select Calibrate to begin the posture recalibration process Follow the calibration steps described in Calibrate Posture on page 8 If you do not respo...

Page 16: ...lready lifted off the skin It may be used if the biosensor begins to peel up at the edges but has not lost contact with the skin Message VitalPatch Not Connected This message indicates that the VitalP...

Page 17: ...tery exhaustion Bluetooth Connection Issues If VistaPoint has issues connecting to or disconnecting from the biosensor the following steps are recommended Ensure that the biosensor is turned ON Note t...

Page 18: ...before you can restart the device next step 2 Restart the VistaTablet by holding the Power Key and the Volume Down Key next to the Power Key down for a few seconds and then releasing 3 A Maintenance...

Page 19: ...lowing tasks Read and understand the Model 3150 Indications for Use Warnings and Cautions Unpack the device Install batteries Attach the wristband Attach the sensor Pairing the Model 3150 Use the foll...

Page 20: ...Point display tap the Pair New button Figure 25 Begin Pairing Process for Pulse Oximeter b VistaPoint prompts you to select the model of the Pulse Oximeter Select Model 3150 Wrist Figure 26 Select Pul...

Page 21: ...aring the sensor and the batteries have not expired Refer to the following topics for routine operating procedures Monitoring Battery Life and Replacing Batteries Pairing a New Model 3150 Model 3150 S...

Page 22: ...mplete a new Model 3150 or other supported Pulse Oximeter may be paired to the VistaPoint application by selecting Pair New If oxygen saturation monitoring is no longer required tap the Disconnect but...

Page 23: ...econnect alerting other users to the current patient status Unexpected disconnect may also occur when the Model 3150 is intentionally removed from the patient for example when monitoring is no longer...

Page 24: ...Operation Before using the Model 3230 Pulse Oximeter with the VistaPoint application refer to the Nonin Medical Model 3230 Instructions for Use to perform the following tasks Read and understand the M...

Page 25: ...Process for Pulse Oximeter b VistaPoint prompts you to select the model of the Pulse Oximeter Select Model 3230 Fingertip Figure 33 Select Pulse Oximeter Model 3230 c VistaPoint begins scanning for de...

Page 26: ...at has previously been paired with the VistaPoint application Step 1 Launch VistaPoint If it is not currently running launch the VistaPoint application Ensure the VitalPatch biosensor on the patient i...

Page 27: ...ation does not provide an indication of Model 3230 battery status However the Model 3230 is capable of performing over 2000 spot checks before the batteries require replacement For information about c...

Page 28: ...the instructions in the Nonin Medical Model 3230 Instructions for Use Model 3230 Status Alerts During normal operation of the Model 3230 the screen of the device may display alerts that indicate devic...

Page 29: ...on Before using the Model UA 651 Blood Pressure Monitor with the VistaPoint application refer to the A D UA 651 Instruction Manual to perform the following tasks Read and understand the Indications fo...

Page 30: ...on until Pr is displayed The device enters Bluetooth pairing mode Figure 39 Placing the Model UA 651 in Pairing Mode d VistaPoint scans for devices and displays a list of valid Bluetooth IDs Select th...

Page 31: ...rocedure to take a spot check blood pressure reading with a Model UA 651 that has previously been paired with the VistaPoint application Step 1 Launch VistaPoint If it is not currently running launch...

Page 32: ...o the A D UA 651 Instruction Manual for application instructions Note If Taking Reading is not displayed on VistaPoint you will need to repeat the pairing process When the reading is complete check th...

Page 33: ...staPoint application again Pairing a New Model UA 651 or Discontinuing Monitoring During normal operation it may be necessary to connect a different Model UA 651 Blood Pressure Monitor to the VistaPoi...

Page 34: ...th the VistaPoint application refer to the A D UC 352 Instruction Manual to perform the following tasks Read and understand the Model UC 352 Warnings and Cautions Unpack the device Install batteries P...

Page 35: ...the Model UC 352 in Pairing Mode d VistaPoint scans for devices and displays a list of valid Bluetooth IDs Select the Bluetooth ID that is printed on the bottom of the UC 352 below the battery compart...

Page 36: ...application Step 1 Launch VistaPoint If it is not currently running launch the VistaPoint application Ensure the VitalPatch biosensor on the patient is paired with VistaPoint and is currently display...

Page 37: ...plete check that the measured weight is displayed in the Weight section of the VistaPoint application Figure 50 Measured Weight Displayed on VistaPoint application Operating the Model UC 352 Refer to...

Page 38: ...t Model UC 352 or other supported scale If weight monitoring is no longer required no additional action is necessary Clean and store the scale per the instructions in the A D Model UC 352 Instruction...

Page 39: ...physician Legal Information 2019 VitalConnect Inc A list of our trademarks can be found at www vitalconnect com All other marks mentioned herein may be trademarks of their respective companies Contact...

Reviews: